Poor write performance on MetroCluster system with EMS event "'ctrl.rdma.failConnect' suppressed 10 times in last 700 seconds"
Applies to
- Fabric-attached MetroCluster
- ONTAP 9
Issue
- Poor write performance on MetroCluster system
- EMS reports events:
DEBUG ctrl.rdma.failConnect: Failed to connect.
DEBUG ems.engine.suppressed: Event 'ctrl.rdma.failConnect' suppressed 10 times in last 700 seconds.
- Read performance is normal