Partitions showing failed after motherboard replace
Applies to
- ONTAP 9
- AFF-A400
- MetroCluster IP
- ADP (Advanced Disk Partitioning)
Issue
- After a motherboard replacement for one node of a 4-node MetroCluster IP, multiple partitions showed failed in the remote plexes of multiple aggregates
Example:
Plex /aggr1/plex1 (offline, failed, inactive) RAID group /aggr1/plex1/rg0 (partial, block checksums) RAID Disk Device HA SHELF BAY CHAN Pool Type RPM Used (MB/blks) Phys (MB/blks) --------- ------ ------------- ---- ---- ---- ----- -------------- -------------- dparity FAILED N/A 1757716/ - parity FAILED N/A 1757716/ - data FAILED N/A 1757716/ - data FAILED N/A 1757716/ - data 0m.i0.1L31P1 0m 10 18 1 SSD N/A 1757716/3599803904 1757724/3599820288 (fast zeroed) data 0m.i0.1L34P1 0m 10 20 1 SSD N/A 1757716/3599803904 1757724/3599820288 (fast zeroed) data 0v.i0.1L36P1 0v 10 22 1 SSD N/A 1757716/3599803904 1757724/3599820288 (fast zeroed) data 0m.i0.1L37P1 0m 10 23 1 SSD N/A 1757716/3599803904 1757724/3599820288 (fast zeroed) data FAILED N/A 1757716/ - data FAILED N/A 1757716/ - data 0m.i0.1L33P1 0m 10 19 1 SSD N/A 1757716/3599803904 1757724/3599820288 (fast zeroed) data 0v.i0.3L35P1 0v 10 21 1 SSD N/A 1757716/3599803904 1757724/3599820288 (fast zeroed) data 0m.i0.0L18P1 0m 11 6 1 SSD N/A 1757716/3599803904 1757724/3599820288 data 0v.i0.3L12P1 0v 11 7 1 SSD N/A 1757716/3599803904 1757724/3599820288 data 0m.i0.1L26P1 0m 11 8 1 SSD N/A 1757716/3599803904 1757724/3599820288 data 0v.i0.1L25P1 0v 11 9 1 SSD N/A 1757716/3599803904 1757724/3599820288 data 0m.i0.1L29P1 0m 11 10 1 SSD N/A 1757716/3599803904 1757724/3599820288 data 0v.i0.3L31P1 0v 11 11 1 SSD N/A 1757716/3599803904 1757724/3599820288 Raid group is missing 6 disks.
- Partition could not be unfailed because the actual container disks were not failed