Partitions showing failed after component replace
Applies to
- ONTAP 9
- AFF-A400
- MetroCluster IP
- ADP (Advanced Disk Partitioning)
- Motherboard/Battery replacement
Issue
- After a component replacement for one node of a 4-node MetroCluster IP, multiple partitions showed failed in the remote plexes of multiple aggregates
Example:
Plex /aggr1/plex1 (offline, failed, inactive)
RAID group /aggr1/plex1/rg0 (partial, block checksums)
RAID Disk Device HA SHELF BAY CHAN Pool Type RPM Used (MB/blks) Phys (MB/blks)
--------- ------ ------------- ---- ---- ---- ----- -------------- --------------
dparity FAILED N/A 1757716/ -
parity FAILED N/A 1757716/ -
data FAILED N/A 1757716/ -
data FAILED N/A 1757716/ -
data 0m.i0.1L31P1 0m 10 18 1 SSD N/A 1757716/3599803904 1757724/3599820288 (fast zeroed)
data 0m.i0.1L34P1 0m 10 20 1 SSD N/A 1757716/3599803904 1757724/3599820288 (fast zeroed)
data 0v.i0.1L36P1 0v 10 22 1 SSD N/A 1757716/3599803904 1757724/3599820288 (fast zeroed)
data 0m.i0.1L37P1 0m 10 23 1 SSD N/A 1757716/3599803904 1757724/3599820288 (fast zeroed)
data FAILED N/A 1757716/ -
data FAILED N/A 1757716/ -
data 0m.i0.1L33P1 0m 10 19 1 SSD N/A 1757716/3599803904 1757724/3599820288 (fast zeroed)
data 0v.i0.3L35P1 0v 10 21 1 SSD N/A 1757716/3599803904 1757724/3599820288 (fast zeroed)
data 0m.i0.0L18P1 0m 11 6 1 SSD N/A 1757716/3599803904 1757724/3599820288
data 0v.i0.3L12P1 0v 11 7 1 SSD N/A 1757716/3599803904 1757724/3599820288
data 0m.i0.1L26P1 0m 11 8 1 SSD N/A 1757716/3599803904 1757724/3599820288
data 0v.i0.1L25P1 0v 11 9 1 SSD N/A 1757716/3599803904 1757724/3599820288
data 0m.i0.1L29P1 0m 11 10 1 SSD N/A 1757716/3599803904 1757724/3599820288
data 0v.i0.3L31P1 0v 11 11 1 SSD N/A 1757716/3599803904 1757724/3599820288
Raid group is missing 6 disks.
- Partition could not be unfailed because the actual container disks were not failed