Nodes reboot with "REBOOT (internal reboot)" after "MEDIATOR DOWN" and "SYNCMIRROR PLEX FAILED" alert

Views:
619
Visibility:
Public
Votes:
0
Category:
metrocluster
Specialty:
MetroCluster
Last Updated:
9/9/2024, 10:25:35 AM

Applies to

  • IP MetroCluster
  • ONTAP 9
  • MetroCluster Compliant Switch (shared switch for MCC backend and other traffic)

Issue

  • Nodes will reboot by triggering the below Autosupports

   HA Group Notification (MEDIATOR DOWN, AUSO DISABLED) ALERT
   HA Group Notification (SYNCMIRROR PLEX FAILED) ALERT
   HA Group Notification (REBOOT (internal reboot)) NOTICE

  • EMS logs will show the indications of mediator disconnect, transport errors, disk read reservation failure on remote drives, takeover disabled errors 
 Thu Mar 02 02:35:13 +1100 [node01: geom: geom.ontap.orphan.removing:notice]: Removing unit 0 type 5.
 Thu Mar 02 02:35:13 +1100 [node01: geom: geom.ontap.orphan.removing:notice]: Removing unit 1 type 5.
 Thu Mar 02 02:35:13 +1100 [node01: pha_remove000: mlm.array.lun.removed:notice]: Array LUN '0f.1' (3337633537306161) is no longer being presented to this node.

 Thu Mar 02 12:17:43 +1100 [node01: disk_admin: disk.readReservationFailed:error]: Disk read reservation failed on 0m.i1.0L14 CDB 0x5e:01 - SCSI:no sense (0 0 0)
 Thu Mar 02 12:17:43 +1100 [node01: disk_admin: disk.readReservationFailed:error]: Disk read reservation failed on 0m.i1.0L15 CDB 0x5e:01 - SCSI:no sense (0 0 0)

 Thu Mar 02 12:17:42 +1100 [node01: cf_main: cf.fsm.backupMailboxError:error]: Failover monitor: partner mailbox error detected.
 Thu Mar 02 12:17:42 +1100 [node01: cf_main: cf.fsm.takeoverOfPartnerDisabled:error]: Failover monitor: takeover of node02 disabled (partner mailbox disks not accessible or invalid).
 Thu Mar 02 12:17:42 +1100 [node01: cf_main: cf.fsm.takeoverByPartnerDisabled:error]: Failover monitor: takeover of node01 by node02 disabled (unsynchronized log).
 Thu Mar 02 12:17:43 +1100 [node01: svc_queue_thread: cf.ic.xferTimedOut:error]: HA interconnect: OFW transfer timed out.
 Thu Mar 02 12:17:43 +1100 [node01: cf_firmware: cf.fm.partnerFwTransition:info]: params: {'progresscounter': '0', 'newstate': 'SF_UNKNOWN', 'prevstate': 'SF_UP'}

 Thu Mar 02 12:17:42 +1100 [node01: scsi_cmdblk_strthr_admin: scsi.cmd.transportErrorEMSOnly:error]: Disk device 0v.i1.1L42: Transport error during execution of command: HA status 0x9: cdb 0x28:00000008:0008. 
 Thu Mar 02 12:17:42 +1100 [node01: scsi_cmdblk_strthr_admin: scsi.cmd.transportErrorEMSOnly:error]: Disk device 0v.i1.1L79: Transport error during execution of command: HA status 0x9: cdb 0x28:00000008:0008. 
  • Below event will be reported in EMS log as reason for reboot 

  Thu Mar 02 12:17:42 +1100 [node01: fmmbx_instanceWorker: kern.shutdown.initiator:debug]: SK reboot was initiated by "maytag.ko::mia_mccip_local_write_partial_fail+568".

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.