Skip to main content
NetApp Knowledge Base

NVIDIA SN2100 switches shown as unsupported

Views:
252
Visibility:
Public
Votes:
0
Category:
metrocluster
Specialty:
metrocluster
Last Updated:

Applies to

  • MetroCluster IP
  • ONTAP 9
  • NVIDIA SN2100 ethernet switches

Issue

  • An NVIDIA SN2100 Ethernet switch might be shown as "Unsupported" in ONTAP Ethernet Switch Health Monitor (CSHM), despite being listed in NetApp Hardware Universe as supported.

  Cluster::> system health alert show
                 Node: Node-01
             Alert ID: UnsupportedSwitch_Alert
             Resource: Switch-01
             Severity: Major
      Indication Time: Fri Jun 07 09:27:23 2024
             Suppress: false
          Acknowledge: false
       Probable Cause: Unsupported Ethernet switch is detected.
      Possible Effect: Communication problems and network connectivity issues occur.
  Corrective Actions: Unsupported Ethernet switch "Switch-01" found.
  Connect a supported Ethernet switch to the network.

  • When checking the switch, you can see that the switch part number is set to X190006-PE:

 cumulus@Switch-01:mgmt:~$ nv show platform hardware
                 operational                      applied
  -------------  -------------------------------  -------
  base-mac       XX:XX:XX:XX:XX:XX
  cpu            x86_64 Intel Atom C2558 2.40GHz
  disk-size      14.00 GB
  manufacturer   Mellanox
  memory         7.49 GB
  model          X86_MSN2100
  onie-version   2021.02-5.3.0006-115200
  part-number    X190006-PE          <<<<<<<<<<
  platform-name  x86_64-mlnx_x86-r0
  port-layout    16 x 100G-QSFP28
  product-name   MSN2100
  serial-number  XXXXXXXXXXXX
  system-mac     XX:XX:XX:XX:XX:XX
  asic-model     Spectrum
  asic-vendor    Mellanox
  cumulus@Switch-01:mgmt:~$

The switch is falsely detected as unsupported due to the switch's part number not being recognized correctly by ONTAP.

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.