NVIDIA 2100 Switch stays down during Metrocluster configuration
Applies to
- ONTAP 9
- Metrocluster
- X1151A SFP Adapter
- X1146A SFP Adapter
- Operating System Cumulus Linux 5.4
- NVIDIA SN2100 Switch
Issue
- After connecting supported copper cables to an NVIDIA SN2100 switch to a compatible adapter, local cluster setup can't be completed due to down ports:
::> Network port show
:
Node: Node01
Speed(Mbps) Health
Port IPspace Broadcast Domain Link MTU Admin/Oper Status
--------- ------------ ---------------- ---- ---- ----- ------ --------
e0M Default - up 1500 auto/1000 -
e0a Default - up 1500 auto/25000 -
e0b Default - up 1500 auto/25000 -
e0e Default - down 1500 auto/auto -
e0f Default - down 1500 auto/auto -
e0g Default - down 1500 auto/auto -
e0h Default - down 1500 auto/auto -
e3a Cluster - down 9000 cars/cars -
e3b Cluster - down 9000 cars/cars -
e4a Default - down 1500 auto/auto -
e4b Default - down 1500 auto/auto -
::> network interface show:
::> net int show
(network interface show)
Logical Status Network Current Current Is
Vserver Interface Admin/Oper Address/Mask Node Port Home
----------- ---------- ---------- ------------------ ------------- ------- ----
Cluster
clus1 up/down 10.0.0.1/16 Node01 e3a true
clus2 up/down 10.0.0.2/16 Node01 e3b true
Default
mgmt1 up/up 10.0.0.5/24 Node01 e0M true