Skip to main content
NetApp Knowledge Base

Metrocluster system switch fc show -connectivity does not give expected output

Views:
58
Visibility:
Public
Votes:
0
Category:
metrocluster
Specialty:
metrocluster
Last Updated:

Applies to

  • Fabric MetroCluster
  • ONTAP 9
  • Brocade Fibre Channel switches

Issue

  • The command system switch fc show -connectivity does not give the expected output.
  • The output under the connectivity section is empty
Example:
Cluster_A::> system switch fc show -switch-name Brocade_10.0.0.1 -connectivity

      Switch Name: Brocade_10.0.0.1
       Switch WWN: 1000d81234510120
       Fabric WWN: 1000d8123457ea98
           Vendor: Brocade
            Model: BrocadeG720
           Errors: -
 Last Update Time: 12/13/2024 13:42:46 +00:00

Connectivity:
Port Name Port Mode Port WWN         Peer Port WWN    Peer Type    Peer Info
--------- --------- ---------------- ---------------- ------------ ---------
-         -         -                -                -            -

 Last Update Time: 12/13/2024 13:40:42 +00:00

Path:
                                                 Switch
                                                   Port
Node                 Adapter        Switch Port   Speed Adapter Type
-------------------- -------------- ----------- ------- --------------
Cluster_A-02         0g             FC port 0/12 16Gbps FCP-Initiator
Cluster_A-02         1a             FC port 0/13 16Gbps FCP-Initiator
Cluster_A-02         fcvi_device_1  FC port 0/4  16Gbps FC-VI
Cluster_A-01         0g             FC port 0/8  16Gbps FCP-Initiator
Cluster_A-01         1a             FC port 0/9  16Gbps FCP-Initiator
Cluster_A-01         fcvi_device_1  FC port 0/0  16Gbps FC-VI

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.