Metrocluster Check returns warning on LIF component
Applies to
- ONTAP 9
- Metrocluster
Issue
- MetroCluster check result shows warnings on LIF component.
::> metrocluster check show
Last Checked On: dd/mm/yyyy hh:mm:ss
Component Result
------------------- ---------
nodes ok
lifs warning
config-replication ok
aggregates ok
clusters oK
MetroCluster check lif show -instance
command gives detailed information about the error.
Name of the Cluster : vserver1
Name of the Vserver : vserver1-mc
Name of the Lif : FC_LIF_1
Description : port-selection
Result of the Check : warning
Additional Information/Recovery Steps: There are no ports on node "node1" connected to fabric "10:00:c4:f5:xx:xx:xx:xx" in the destination cluster. Cannot place FC LIF "FC_LIF_1" hosted on the source cluster port "10a" of "FC" adapter type for Vserver "vserver1-mc". Check the cabling to ensure that ports on the destination cluster node (DR partner) are connected to the same fabric as the source cluster port hosting the primary Vserver FC LIF. Use "fcp adapter show -fields fabric-name" command to view the port-fabric connectivity information. After ensuring proper fabric connectivity, run "metrocluster check lif repair-placement" command on the source cluster with the Vserver name and LIF name as inputs to perform lif placement followed by "metrocluster check lif show" to verify the results of the command.