Skip to main content
NetApp Knowledge Base

Metrocluster Check returns warning on LIF component

Views:
19
Visibility:
Public
Votes:
0
Category:
metrocluster
Specialty:
metrocluster
Last Updated:

Applies to

  • ONTAP 9
  • Metrocluster

Issue

  • MetroCluster check result shows warnings on LIF component.

::> metrocluster check show

Last Checked On: dd/mm/yyyy hh:mm:ss

Component            Result
------------------- ---------
nodes                ok
lifs                 warning
config-replication   ok
aggregates           ok
clusters             oK

  • MetroCluster check lif show -instance  command gives detailed information about the error.

Name of the Cluster    : vserver1
Name of the Vserver    : vserver1-mc
Name of the Lif        : FC_LIF_1
Description            : port-selection
Result of the Check    : warning
Additional Information/Recovery Steps: There are no ports on node "node1" connected to fabric "10:00:c4:f5:xx:xx:xx:xx" in the destination cluster. Cannot place FC LIF "FC_LIF_1" hosted on the source cluster port "10a" of "FC" adapter type for Vserver "vserver1-mc". Check the cabling to ensure that ports on the destination cluster node (DR partner) are connected to the same fabric as the source cluster port hosting the primary Vserver FC LIF. Use "fcp adapter show -fields fabric-name" command to view the port-fabric connectivity information. After ensuring proper fabric connectivity, run "metrocluster check lif repair-placement" command on the source cluster with the Vserver name and LIF name as inputs to perform lif placement followed by "metrocluster check lif show" to verify the results of the command.

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.