MetroCluster scsi cmd targetstatus error target status busy
Applies to
- Fabric MetroCluster
- ONTAP 9
Issue
- The following errors are seen in EMS logs:
CL01N01: slifc_intrd: scsi.cmd.targetStatus:error]: Unknown device SWITCH01:10.126L25: Target Status Busy: cdb 0x12
- The following errors are seen in the logs from the ATTO FibreBridge connected to SWITCH01-10:
59E9FE 13:34:29 09/12/24 INFO State chg 500a09800867999c from Good to VirtualDev_Busy
59E9FF 13:34:29 09/12/24 INFO 500a09800867999c Virtual device busy - timeout started
59EA00 13:34:29 09/12/24 INFO SAS Port A Discovery starting
59EA01 13:34:29 09/12/24 INFO SAS Port A Discovery complete