Skip to main content
NetApp Knowledge Base

MetroCluster ISL links not coming up with X65406 transceivers

Views:
34
Visibility:
Public
Votes:
0
Category:
metrocluster
Specialty:
metrocluster
Last Updated:

Applies to

  • ONTAP 9
  • MetroCluster IP
  • X65406 100Gb LWL transceivers
  • Cisco back-end IP switches 

Issue

  • Remote ISLs are not coming online during the initial setup of the system
  • show interface brief status of the port is Link not connected
`show interface brief`

Eth1/15         1       eth  trunk  down    Link not connected       auto(D) 10
  • Rx power is not detected by the switch:
`show interface transceiver detail`
 
Ethernet1/15
    transceiver is present
    type is QSFP-100G-CWDM4
    name is FINISAR CORP.
    part number is FTLC1157RGPL
Lane Number:1 Network Lane
           SFP Detail Diagnostics Information (internal calibration)
  ----------------------------------------------------------------------------
                Current              Alarms                  Warnings
                Measurement     High        Low         High          Low
  ----------------------------------------------------------------------------
  Temperature   46.84 C        75.00 C     -5.00 C     70.00 C        0.00 C
  Voltage        3.26 V         3.63 V      2.97 V      3.46 V        3.13 V
  Current       35.65 mA       77.00 mA    13.00 mA    72.00 mA      18.00 mA
  Tx Power       1.57 dBm       5.49 dBm   -8.01 dBm    2.49 dBm     -4.00 dBm
  Rx Power          N/A         3.49 dBm  -16.02 dBm    2.49 dBm    -12.00 dBm
  • Local loop back test show the link is coming up
  • Cabling both local switches brings the link up

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.