Issue

  • showing high cluster latency in qos statistics latency
  • Event log reporting multiple scsi.cmd errors
    scsi_cmdblk_strthr_admin: scsi.cmd.abortedByHost:error]: Disk device 0v.i1.2L5: Command aborted by host adapter: HA status 0x13: cdb 0x28:1b0153c0:001a
  • Increasing error counters shown in "show interface ethernet "interface_name"" on one Switch port
    Total Packets Received with MAC Errors......... 15427
    Jabbers Received............................... 14430
  • Shutting down the suspicious ports, brings latency back to normal
  • Replacing SFPs and cable doesn't fix the issue
  • wafl.cp.toolong might be reported in event log

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.