InterconnectAdapterOfflineAlert FCVI port 2x in a two-node stretch MetroCluster
Applies to
- 2 Node
- Stretch MetroCluster
- ONTAP 9
- FC-VI errors
Issue
InterconnectAdapterOfflineAlertreported on FCVI port 2a in a two-node bridge-attached stretch MetroCluster with no switches.- One node panics with message:
PANIC: nested machine check exception detected on CPU 12, no coredump will be generated.
- System Health Alert shows:
::> system health alert showNode: node-01Alert ID: InterconnectAdapterOfflineAlertResource: fcvi_device_0Severity: MajorIndication Time: Tue Mar 18 09:18:56 2025Suppress: falseAcknowledge: falseProbable Cause: Physical link on port 2a is offline.Possible Effect: DR protection of NVRAM mirror might be compromised. Corrective Actions: 1. Ensure that the FC-VI link has not been tampered with.2. Verify that the physical status of the FC-VI adapter is "Up" by using the command "metrocluster interconnect adapter show".3. If the configuration includes fabric switches, ensure that they are properly cabled and configured.- Event logs show the following messages:
Cluster-1:
Tue Aug 20 12:55:29 +0000 [node-01A: ispfcvi2500_port2: fcvi.update.link.state:notice]: FC-VI adapter: Physical link is down on port 2a.Cluster-2: