How to troubleshoot "DomainMismatchFromNodeToShelf Alert" on MetroCluster IP
Applies to
- ONTAP 9
- MetroCluster IP
- NS224 Shelves - Switch attached
- Cisco 9336C-FX2
Description
ONTAP system health monitor reports "DomainMismatchFromNodeToShelf_Alert" on a MetroCluster IP system with switch attached NS224 shelves.
Node ClusterA-02
Monitor system-connectAlert ID DomainMismatchFromNodeToShelf_AlertAlerting Resource IP_Switch_x_2Subsystem SAS-connect_ClusterIndication Time <date>Perceived Severity MajorProbable Cause Configuration_errorDescription The storage domain between the nodes ClusterA-01, ClusterA-02 and switch IP_Switch_x_2 is different from the domain between the switch and shelves 4.40, 4.50, 4.60, 4.70.Corrective Actions Connect the switch IP_Switch_x_2 to both the node and the shelves with the same storage domain, following the guide applicable to your shelf.Possible Effect This issue will affect conversions to direct-attached storage.Additional Information Switch Name: IP_Switch_x_2Nodes: ClusterA-01, ClusterA-02Ports: ClusterA-01:e10a, ClusterA-02:e10aConnected Shelves: 4.40, 4.50, 4.60, 4.70Nodes Connected to Switch Port Range A: ClusterA-01, ClusterA-02Nodes Connected to Switch Port Range B:Alerting Resource Name Switch name: IP_Switch_x_2
