Skip to main content
NetApp Knowledge Base

High CPU observed on Brocade switch (FabOS 8.2.3)

Views:
3,243
Visibility:
Public
Votes:
4
Category:
metrocluster
Specialty:
metrocluster
Last Updated:

Applies to

  • MetroCluster FC
  • Brocade FC Switches
  • Brocade Fabric OS (FOS)
  • ONTAP 9

Issue

  • Log in to the switch takes quite a long time
  • Command outputs take a very long time
  • FabOS firmware update times out
  • Observed high CPU usage on all 4 Brocade FC Switches when running the command top

Cpu(s): 83.9%us, 15.1%sy,  0.0%ni,  0.0%id,  0.0%wa,  1.0%hi,  0.0%si,  0.0%st
Mem:   1024012k total,   800440k used,   223572k free,    42140k buffers
Swap:        0k total,        0k used,        0k free,   489864k cached
  PID USER      PR  NI  VIRT  RES  SHR S %CPU %MEM    TIME+  COMMAND
 1658 0         16   0  103m  18m  13m S 96.1  1.9  32709:36 snmpd
 1578 0         16   0  126m  26m  14m S  1.0  2.6 688:42.94 mdd0
 1633 0         15   0  122m  16m  11m S  1.0  1.6 659:22.04 nsd0
 6245 7003      16   0  2816 1304 1036 R  1.0  0.1   0:00.24 top

 

2021/12/01-07:34:12:275938, [MAPS-1002], 14131470/4797, FID 128, ERROR, SANSW02, Chassis, Condition=CHASSIS(CPU>80.00),
 Current Value:[CPU, 99.00 %], RuleName=CHASSIS_CPU_UTILIZATION, Dashboard Category=Switch Resource., raslogAction.c, 
 line: 170, comp:md, ltime:2021/12/01-07:34:12:275169

2021/12/01-07:54:12:258987, [MAPS-1002], 14131882/4798, FID 128, ERROR, SANSW02, Chassis, Condition=CHASSIS(CPU>80.00), 
Current Value:[CPU, 100.00 %], RuleName=CHASSIS_CPU_UTILIZATION, Dashboard Category=Switch Resource., raslogAction.c, 
line: 170, comp:md, ltime:2021/12/01-07:54:12:257628

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.