Fabric MetroCluster: Multiple disks missing
Applies to
- Fabric MetroCluster
- ONTAP 9
Issue
Disks are frequently 'missing' in a Fabric MetroCluster:
Thu Oct 05 06:53:42 0200 [node1: svc_queue_thread: cf.disk.inventory.mismatch:error]: Status of the disk switch-01:13.126L34 (00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000) has recently changed or the node (node1) is missing the disk.
Thu Oct 05 21:49:30 0200 [node1: svc_queue_thread: cf.disk.inventory.mismatch:error]: Status of the disk ?.? (00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000) has recently changed or the node (node1) is missing the disk.
Thu Oct 05 22:47:38 0200 [node1: config_thread: raid.config.filesystem.disk.missing:info]: File system Disk /aggr1/plex1/rg6/switch-01:14.126L143 Shelf 1 Bay 0 [NETAPP X425_HCBFE1T2A10 NA06] S/N [XXXXXXXX] UID [00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000] is missing.
Thu Oct 05 22:47:57 0200 [node1: config_thread: raid.rg.recons.missing:notice]: RAID group /aggr1/plex1/rg6 is missing 1 disk(s).
Thu Oct 05 22:47:57 0200 [node1: config_thread: raid.rg.recons.info:notice]: Spare disk switch-01:17.126L1019 will be used to reconstruct one missing disk in RAID group /aggr1/plex1/rg6.
Thu Oct 05 22:48:20 0200 [node1: config_failed_disk: callhome.fdsk.missing:error]: Call home for FILESYSTEM DISK MISSING