Fabric MetroCluster: DISK REDUNDANCY FAILED
Applies to
- Fabric MetroCluster
- ONTAP 9
- DISK REDUNDANCY FAILED autosupport(s)
Issue
- Repeated
DISK REDUNDANCY FAILEDautosupports received
- One ATTO bridge SAS port is observing a high number of errors:
Example:
ClusterA::> system node run -node ClusterA-01 -command storage show bridge -v...
Bridge: FC-Switch-A1:10.126L0
Serial: FB7500N000000
Vendor: ATTO
WWN: 2000000000000000
Model: FibreBridge 7500N
Rev: 3.25
...
SAS Port B:
MINI_SAS_HD Vendor: Amphenol
MINI_SAS_HD Part Number: 112-00439
MINI_SAS_HD Type: Passive Copper 5m ID:01
MINI_SAS_HD Serial Number: APF00000000000
Invald Disprt Loss Phy Phy CRC
DWord Error Sync Reset Change Error
Phy State Speed Count Count Count Prob Count Count
--- ------- --------- ------ ------ ------ ------ ------ ------
0 up 12.0 Gb/s 29 23 1 0 6 0
1 up 12.0 Gb/s 32 27 1 0 6 0
2 up 12.0 Gb/s 24 18 1 0 6 0
3 up 12.0 Gb/s 28 19 1 0 6 0