FC Initiator Adapter offline in MetroCluster

Views:
777
Visibility:
Public
Votes:
0
Category:
metrocluster
Specialty:
MetroCluster
Last Updated:

Applies to

  • ONTAP 9
  • Fabric MetroCluster
  • FAS/AFF Systems

Issue

  • FC Adapter is offline in Fabric MetroCluster configuration:

cluster1::> system node run -node node1 -command sysconfig -a

slot 1: FC Host Adapter 1a (Emulex XE501 rev. 1, <OFFLINE (hard)>)
                 Board name:        111-03648
                 Serial Number:     FP12345678
                 Firmware rev:      11.4.277.0
                 Host Port Id:      N/A
                 FC Node Name:      2:000:00109b:ea9206
                 FC Port Name:      1:000:00109b:ea9206
                 Link Data Rate:    N/A

  • The following alert is reported in the event logs:

[Node-01: nchmd: hm.alert.raised:alert]: Alert Id = StorageFCAdapterFault_Alert , Alerting Resource = 10000010XXXX206 raised by monitor node-connect

  • The MetroCluster node health is degraded because of that:

cluster1::> system health subsystem show
Subsystem         Health
----------------- ------------------
SAS-connect       ok
Environment       ok
Memory            ok
Service-Processor ok
Switch-Health     ok
CIFS-NDO          ok
Motherboard       ok
IO                ok
MetroCluster      ok
MetroCluster_Node degraded
FHM-Switch        ok
FHM-Bridge        ok
SAS-connect_Cluster ok
13 entries were displayed.

  • The node configuration may change to "Multi-Path" instead of "Quad-Path" configuration.
    Fri Jun 07 01:10:23 +0200 [ClusterA-01: start_asup_collector_thread: shelf.config.tompha:info]: System has transitioned to multi-path HA attached storage
  • From the switch logs, it is observed that the switch port connected to the affected FC port reports No_Sync or No_Light:

MCC-sw2:admin> switchshow
switchName: MCC-sw2
switchType:  181.0
switchState: Online
switchMode:  Native

Index Port Address  Media Speed   State       Proto
==================================================
   8   8   070800   id    32G     No_Sync     FC

  • The cable between the node FC port and the switch port is reseated.
  • One or more disks reporting fewer than 8 paths (per cluster)/4 paths (per node):
    ::> storage show disk -fields path-count -path-count !8 -type !LUN

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.