FC Initiator Adapter offline in MetroCluster
Applies to
- ONTAP 9
- Fabric MetroCluster
- FAS/AFF Systems
Issue
- FC Adapter is offline in Fabric MetroCluster configuration:
cluster1::> system node run -node node1 -command sysconfig -a
slot 1: FC Host Adapter 1a (Emulex XE501 rev. 1, <OFFLINE (hard)>)
Board name: 111-03648
Serial Number: FP12345678
Firmware rev: 11.4.277.0
Host Port Id: N/A
FC Node Name: 2:000:00109b:ea9206
FC Port Name: 1:000:00109b:ea9206
Link Data Rate: N/A
- The following alert is reported in the event logs:
[Node-01: nchmd: hm.alert.raised:alert]: Alert Id = StorageFCAdapterFault_Alert , Alerting Resource = 10000010XXXX206 raised by monitor node-connect
- The MetroCluster node health is degraded because of that:
cluster1::> system health subsystem show
Subsystem Health
----------------- ------------------
SAS-connect ok
Environment ok
Memory ok
Service-Processor ok
Switch-Health ok
CIFS-NDO ok
Motherboard ok
IO ok
MetroCluster ok
MetroCluster_Node degraded
FHM-Switch ok
FHM-Bridge ok
SAS-connect_Cluster ok
13 entries were displayed.
- The node configuration may change to "Multi-Path" instead of "Quad-Path" configuration.
Fri Jun 07 01:10:23 +0200 [ClusterA-01: start_asup_collector_thread: shelf.config.tompha:info]: System has transitioned to multi-path HA attached storage
- From the switch logs, it is observed that the switch port connected to the affected FC port reports
No_Sync
orNo_Light:
MCC-sw2:admin> switchshow
switchName: MCC-sw2
switchType: 181.0
switchState: Online
switchMode: Native
Index Port Address Media Speed State Proto
==================================================
8 8 070800 id 32G No_Sync FC
- The cable between the node FC port and the switch port is reseated.
- One or more disks reporting fewer than 8 paths (per cluster)/4 paths (per node):
::> storage show disk -fields path-count -path-count !8 -type !LUN