DualControllerNonHa_Alert generated when adding 2 nodes to Metrocluster
Applies to
- Metrocluster IP
- Adding another HA pair to Metrocluster (increasing to an 8-node MCC-IP configuration)
Issue
- Adding a new HA pair to an existing Metrocluster resulted in the alert
::*> system health alert show Node: Node-01 Alert ID: DualControllerNonHa_Alert Resource: Shelf 3.10 Severity: Major Indication Time: Fri Nov 21 13:33:33 2025 Suppress: false Acknowledge: false Probable Cause: Storage shelf 10 is connected to two controllers (Node-01, Node-02) that are not an HA pair. Possible Effect: Access to shelf 3.10 will be lost with a single controller failure. Corrective Actions: 1. Halt all controllers that are connected to shelf 3.10. 2. Connect shelf 3.10 to both HA controllers following the guide applicable to your shelf. 3. Reboot the halted controllers.