ClusterIfOutErrorsWarn_Alert reported against node interface
Applies to
- ONTAP 9
 - Cisco Nexus 3232C cluster switches
 - NX-OS 9.3(8) and lower
 - MetroCluster IP
 
Issue
- The event logs report the following health alerts:
 
[node-01: mgwd: callhome.hm.alert.major:alert]: Call home for Health Monitor process cshm: ClusterIfOutErrorsWarn_Alert[Switch1 (XX)/Ethernet1/10].
- CRC errors are reported on the node interface that is connected to the affected switch port in 
ifstat -aoutput: 
-- interface  e0a  (1 day, 5 hours, 12 minutes, 44 seconds) --
RECEIVE
 Total frames:      177m | Frames/second:    1689  | Total bytes:      1083g
 Bytes/second:    10306k | Total errors:    37713  | Errors/minute:      22 
 Total discards:      0  | Discards/minute:     0  | Multi/broadcast: 68250 
 Non-primary u/c:     0  | CRC errors:      37709  | Runt frames:         0 
 Fragment:            0  | Long frames:         0  | Jabber:              0 
 Length errors:       4  | No buffer:           0  | Xon:                 0 
 Xoff:                0  | Jumbo:             120m | Noproto:             0 
 Error symbol:        0  | Illegal symbol:      0  | Bus overruns:        0 
 Queue drops:         0  | LRO segments:    77977k | LRO bytes:        1076g
 