ClusterIfOutErrorsWarn_Alert reported against node interface
- Views:
- 301
- Visibility:
- Public
- Votes:
- 0
- Category:
- metrocluster
- Specialty:
- metrocluster
- Last Updated:
- 2/26/2025, 2:23:42 PM
Applies to
- ONTAP 9
- Cisco Nexus 3232C cluster switches
- NX-OS 9.3(8) and lower
- MetroCluster IP
Issue
- The event logs report the following health alerts:
[node-01: mgwd: callhome.hm.alert.major:alert]: Call home for Health Monitor process cshm: ClusterIfOutErrorsWarn_Alert[Switch1 (XX)/Ethernet1/10].
- CRC errors are reported on the node interface that is connected to the affected switch port in
ifstat -a
output:
-- interface e0a (1 day, 5 hours, 12 minutes, 44 seconds) --
RECEIVE
Total frames: 177m | Frames/second: 1689 | Total bytes: 1083g
Bytes/second: 10306k | Total errors: 37713 | Errors/minute: 22
Total discards: 0 | Discards/minute: 0 | Multi/broadcast: 68250
Non-primary u/c: 0 | CRC errors: 37709 | Runt frames: 0
Fragment: 0 | Long frames: 0 | Jabber: 0
Length errors: 4 | No buffer: 0 | Xon: 0
Xoff: 0 | Jumbo: 120m | Noproto: 0
Error symbol: 0 | Illegal symbol: 0 | Bus overruns: 0
Queue drops: 0 | LRO segments: 77977k | LRO bytes: 1076g