Automatic switchover disabled: Mediator mailbox disk not healthy
Applies to
- MetroCluster IP
- ONTAP Mediator
- ONTAP 9
Issue
- EMS reports Automatic switchover disabled.
Wed Feb 11 01:51:02 +0800 [XXXXXXXXXX: cf_worker: cf.mccip.med.auso.stDisabled:error]: Automatic switchover disabled: Mediator mailbox disk not healthy
Wed Feb 11 01:51:02 +0800 [XXXXXXXXXX: cf_worker: callhome.mccip.auso.disabled:alert]: Callhome for MEDIATOR DOWN, AUSO DISABLED
- EMS reports iSCSI session of Mediator timeout error.
[XXXXXXXXXXX: kernel: iscsi.session.stateChanged:notice]: iSCSI session state is changed to Reconnecting for the target iqn.2012-05.local:mailbox.target.12345678-c11z-11ts-8674-d039ea1b2f15:a29ad491-c691-11ea-8596-g347ea1b8403:1 (type: mailbox, address: 192.1XX.XX.X). Reason: no ping reply after 5 seconds.
[XXXXXXXXXXX: kernel: iscsi.session.stateChanged:notice]: iSCSI session state is changed to Reconnecting (destroy sim) for the target iqn.2012-05.local:mailbox.target.12345678-c11z-11ts-8674-d039ea1b2f15:a29ad491-c691-11ea-8596-g347ea1b8403:1 (type: mailbox, address: 192.1XX.XX.X). Reason: session login timed out 2 times.