iSCSI throughput only uses one LACP link on client during testing such as Oracle SLOB
Applies to
- ONTAP 9
- ISCSI
- LACP in use on client
Issue
- Lower throughput is seen than expected, especially if comparing to another node or cluster, or server
- Example:
nmon
shows only one 10 GbE link (p4p2
) having a receive value but the other does not (p3p2
) for a high read throughput of ~1 GB/s (maxing one of two 10 GbE links)