Answer

  • In a SAN environment  prior to version 9.11.1 , FC/ISCSI lifs do not failover.
  • It is then up to the host to manage the failover of traffic to the other available paths using  MPIO (Multipathing) software when the target path going to the Node hosting the lun goes down during Takeover/Giveback or during Node going offline.
  • As long as we have the appropriate MPIO software for the host OS installed and Host has access to both nodes , we should not encounter any issues with TO/GB.

Additional Information

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.