FlexArray backend 3rd party storage panic causes aggregate and disk unknown
Applies to
- ONTAP FlexArray
- EMC Unity 600 Hybrid Flash Storage
Issue
- Backend EMC UNITY 600 panics and failover event cause ONTAP to display disks as
broken disk showdisplays LUNs ascontainer-type unknown- Aggregate status
unknown - No disks are listed in affected aggregate in
storage aggregate show - Unable to unfail unknown disks
- Alert:
ARRAY LUN CONNECTED USING ONLY ONE PATH - No
Bad VolinfoorcheckConditionfound in EMS storage show <unknown disk label>indicates active optimized and un-optimized paths are mixed up between nodes.
Acc Use --- --- AO INU AO INU ANO RDY ANO RDY AO INU AO INU AO RDY AO RDY
- Expected:
Acc Use --- --- ANO RDY ANO RDY AO INU AO INU ANO RDY ANO RDY AO INU AO INU