FlexArray backend 3rd party storage panic causes aggregate and disk unknown
- Views:
- 192
- Visibility:
- Public
- Votes:
- 0
- Category:
- v-series-flexarray
- Specialty:
- san
- Last Updated:
- 3/10/2022, 8:44:59 AM
Applies to
- ONTAP FlexArray
- EMC Unity 600 Hybrid Flash Storage
Issue
- Backend EMC UNITY 600 panics and failover event cause ONTAP to display disks as
broken
disk show
displays LUNs ascontainer-type unknown
- Aggregate status
unknown
- No disks are listed in affected aggregate in
storage aggregate show
- Unable to unfail unknown disks
- Alert:
ARRAY LUN CONNECTED USING ONLY ONE PATH
- No
Bad Volinfo
orcheckCondition
found in EMS storage show <unknown disk label>
indicates active optimized and un-optimized paths are mixed up between nodes.
Acc Use --- --- AO INU AO INU ANO RDY ANO RDY AO INU AO INU AO RDY AO RDY
- Expected:
Acc Use --- --- ANO RDY ANO RDY AO INU AO INU ANO RDY ANO RDY AO INU AO INU