FLI disk shows broken post migration
Applies to
- Offline FLI
- Ontap 9.x
- Thirdparty storage
Issue
- FLI disk shows as broken on Ontap CLI post offline FLI migration.
- All the initiators are removed from the zoning on switch end.
AFF-C400::> storage errors show
Disk: HPE-1.14
UID: 600C0FF0:003B55EA:6FE71563:01000000:00000000:00000000:00000000:00000000:00000000:00000000
--------------------
HPE-1.14 (600c0ff0003bxxyyxyxyxyy301000000): This array LUN is an unknown device.
HPE-1.14 (600c0ff0003b5xxyyxyxyxyy301000000): This array LUN is only available on one path. Proper configuration requires two paths.
This disk is in a failed state with the outage reason "init failed". The Disk needs to be removed and replaced.
- As a troubleshooting step Ontap FC Initiator ports can be made offline to make sure there is no active connection to the third party storage.