  • Brocade Fabric OS (FOS)

Issue

  • SYSCONFIG-A shows adapter is down with status LINK NOT CONNECTED:

slot 2: Fibre Channel Target Host Adapter 2a
        (Emulex LPe32000 (LPe32004) rev. 12, <LINK NOT CONNECTED>)

  • FCP-ADAPTER.XML or network fcp adapter show -instance shows adapter's speed is set to 16G:

Operational Status    link not connected

Data Link Rate (Gbit)     16

  • NETWORK-INTERFACE.XML or network interface show -instance shows all LIFs on the adapter are down, with extended status LIF not initialized:

Operational Status    down

Extended Status    LIF not initialized

  • EMS log shows a link break:

Tue Sep 12 15:33:52 +0000 [node1: fct_tpd_work_thread_0: scsitarget.slifct.linkBreak:error]: Link break detected on Fibre Channel target HBA 2a with event status 1 , topology type 1, status1 0x0, status2 0x0.

  • Brocade FOS switchshow shows port is disabled due to throttling and speed is fixed to 32G:
Index Port Address  Media Speed   State       Proto
==================================================
   4   4   010400   id    32G   No_Sync     FC  Disabled (Port Throttled)
  • Brocade FOS clihistory --showall shows the port speed was configured to 32G, without autonegotiation, at the same time as the link break:
Date & Time                      Message
Tue Sep 12 15:33:55 2023         admin, FID 128, 10.48.48.12, portcfgspeed 4 32

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.