Misconfigured virus scan server causes Nblade.vscanBadIPPrivAccess errors
Applies to
- ONTAP 9
- CIFS
- VSCAN
Issue
- Misconfigured virus scan server is unable to effectively connect the
ONTAP_Admin$
share - The ONTAP AV Connector on the server can connect to
IPC$
, which is distinct from the scan engine's connection - EMS / event log show contains events such as the folllowing
-
6/18/2024 15:39:27 OntapCluster1 ERROR Nblade.vscanBadUserPrivAccess: For Vserver "SVM1", the attempt to connect to the privileged ONTAP_ADMIN$ share by the client "10.0.0.200" is rejected because its logged-in user "DOMAIN\VScanner01$" is not configured in any of the Vserver active scanner pools.
-