Skip to main content
NetApp Knowledge Base

Error "Device attached to the system is not functioning" seen in the backup application log on IBM Tivoli Storage Manager

Views:
897
Visibility:
Public
Votes:
1
Category:
ontap-9
Specialty:
nas
Last Updated:

Applies to

  • ONTAP 9.5
  • Named pipe
  • IBM Tivoli Storage Manager

Issue

Not able to perform operation on the UNIX FIFO files - named pipe files in the CIFS share
Error is seen in the application log of IBM Tivoli Storage Manager :
 
Received Win32 RC 31 (0x0000001f) from GetBackupStreamSize(): uc_CreateFile. Error description: A device attached to the system is not functioning.
 
 
This is the Windows error if file copy is performed:
 
named_pipe_ONTAP_9_5.png
 
This is how that file looks from the NFS client:
 
bash-3.2# ls -la
total 24
drwxr-xr-x  2 root  wheel  4096 Oct 16 09:00 .
drwxr-xr-x  4 root  wheel  4096 Oct 15 12:21 ..
drwxrwxrwx  9 root  wheel  4096 Oct 16 08:05 .snapshot
-rw-r--r--  1 root  wheel     0 Oct 16 08:59 1
-rw-r--r--  1 root  wheel     0 Oct 16 08:59 file
prw-r--r--  1 root  wheel     0 Oct 16 09:00 test
 
 

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.