Skip to main content
NetApp Knowledge Base

CIFS authentication fails during tkeover due to DNS communication failure on node-02

Views:
53
Visibility:
Public
Votes:
0
Category:
fas-systems
Specialty:
nas
Last Updated:

Applies to

  • ONTAP 9
  • CIFS

Issue

  • After controller takeover from node-01 to node02, CIFS authentication fails on node-02 due to inability to communicate with DNS server
  • This results in CIFS service disruption
Example:
9/1/2025 08:54:09 node-02 ERROR secd.cifsAuth.problem: vserver (svm1) General CIFS authentication problem. Error: User authentication procedure failed
CIFS SMB2 Share mapping - ClientIp=10.xxx.xxx.xxx
[0ms] Login attempt by domain user 'DOMAIN\User1' using NTLMv2 style security
[2006] Failed to connect to 10.xxx.xxx.xxx for DNS via Source Address 192.xxx.xxx.xxx: Operation timed out
[3013] FAILURE: Unable to contact DNS to discover domain controllers.
[3014] Unable to make a connection (NetLogon: DOMAIN.COM), Result: RESULT_ERROR_DNS_CANT_REACH_SERVER
[3015] CIFS authentication failed
 
ERROR secd.dns.server.timed.out: DNS server 10.xxx.xxx.xxx did not respond to vserver=svm1 within timeout interval.
ERROR secd.dns.srv.lookup.failed: DNS server failed to lookup service (_ldap._tcp.dc._msdcs.DOMAIN.COM) for vserver (svm1) with error (Operation timed out).

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.