A data port went down after the ONTAP upgrade
Applies to
- ONTAP 9
- ANDU (Automated Non-disruptive upgrade)
- FAS/AFF/ASA
- 10G/25G Ethernet Controller CX5 in 25G mode
- Cisco Nexus 9K-C93180YC-FX
Issue
- After performing the ONTAP upgrade, one or more ports on the CX5 network card do not automatically come back online, while all other ports do.
- This is observed even though:
- No hardware or switch errors (CRC, physical faults) are present.
- The issue might occur across multiple clusters.
- Relevant Logs:
[?] Fri Apr 24 19:38:38 +1000 [Node1: vifmgr: vifmgr.reach.unassn:notice]: Network port e3a on node Node1 is not assigned to any broadcast domain. No broadcast domains appear to be reachable from this port.
[?] Fri Apr 24 19:38:38 +1000 [Node1: vifmgr: vifmgr.reach.skipped:notice]: Network port e3a on node Node1 was not scanned for reachability because it was administratively or operationally down at the time of the scan.
[?] Fri Apr 24 19:38:39 +1000 [Node1: vifmgr: vifmgr.portdown:notice]: A link down event was received on node Node1, port e3a.