Issue
- Workloads on hosts accessing LUNs via iSCSI incur significant application and client latency
- ONTAP has low latency (less than 5 milliseconds) in latency counters
- Network latency in SAN environment is seen in the
Network
delay center orNetwork
in Active IQ Unified Manager (AIQUM) but not inNetwork Processing
under the Cluster Components volume view
Example:
qos statistics volume latency show
shows high latency in the Network
column for three SAN workloads
cluster::> qos statistics volume latency show -node san_node1
Workload ID Latency Network Cluster Data Disk QoS NVRAM Cloud ----------- ------ ---------- ---------- ---------- ---------- ---------- ---------- ---------- ---------- volume_SAN1 17882 20.51ms 20.51ms 0ms 0ms 0ms 0ms 0ms 0ms volume_SAN2 5232 15.00ms 15.00ms 0ms 0ms 0ms 0ms 0ms 0ms volume_SAN3 17160 16.00ms 16.00ms 0ms 0ms 0ms 0ms 0ms 0ms