Applies to

  • ONTAP 9
  • AFF & FAS
  • Input/Output Module (IOM)

Issue

  • Highly utilized aggregate resulting in high read and write latency 
  • Retrived shelf number of highly utilized aggregate from sysconfig -r in autosupports
  • Found IOM type installed from sysconfig -a  in autosupports using the above shelf number
  • From perfecto, verified that the transfer rate was saturating IOM6 
  • Transfer rate on port 3b was approx. 750MB/s, IOM6 recommended max transfer rate is approx. 700MB/s

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.