High latency due to IOM6 bottleneck
Applies to
- ONTAP 9
- AFF & FAS
- Input/Output Module (IOM)
Issue
- Highly utilized aggregate resulting in high read and write latency
- Retrived shelf number of highly utilized aggregate from
sysconfig -r
in autosupports
- Found IOM type installed from
sysconfig -a
in autosupports using the above shelf number
- From perfecto, verified that the transfer rate was saturating IOM6
- Transfer rate on port 3b was approx. 750MB/s, IOM6 recommended max transfer rate is approx. 700MB/s