Answer

No,  it doesn't. Here is how it works.

  • Adjusting the Volume Tiering Minimum Cooling Days on a given volume doesn't reset any previously accumulated IDR counters on a volume, preserving all current counters.
  • Adjusting the Volume Tiering Minimum Cooling Days to a smaller value,  allow any previously blocks that were marked aged 30 days or more to begin to tier out accordingly.

Additional Information

  • The adjustment of the Volume Tiering Minimum Cooling Days is avaliable starting with ONTAP 9.8.
  • The IDR counters will only be reset by either a volume move operation, or by a node reboot.

 

 

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.