API disappears chassis state error
Applies to
- ONTAP 9.6 or later
 - API
 
Issue
- Chassis state is error via API Link: https://cluster_mgmt_LIF/api/cluster/chassis?fields=*
 
{"records": [{"id": "BPJWX7901654512","state": "error","nodes": [{"name": "fas2554-dal-1a","uuid": "70e941f0-2cff-11ed-ac6f-00a098ca47ad","position": "top",............"name": "fas2554-dal-1b","uuid": "72b197d6-2cff-11ed-8dca-00a0987255ae","position": "bottom",- Command "
system chassis show" disappears chassis is degraded. 
::> system chassis showChassis ID                 Status          List of Nodes-------------------------- --------------- ----------------------------------BPJWX7901654512            degraded        fas2554-dal-1a, fas2554-dal-1b- Command "
system chassis fru show" disappears controller is degraded 
::> system chassis fru show
Chassis ID          FRU        Type     State       Nodes Sharing the FRU
------------------- ---------- -------- ----------- -----------------------
BPJWX7901654512     fas2554-dal-1b
                               controller
                                        degraded    fas2554-dal-1b
BPJWX7901654512     fas2554-dal-1a
                               controller
                                        ok          fas2554-dal-1a
BPJWX7901654512     PSU1 FRU   psu      GOOD        fas2554-dal-1a,
                                                    fas2554-dal-1b
BPJWX7901654512     PSU2 FRU   psu      GOOD        fas2554-dal-1a,
                                                    fas2554-dal-1b
BPJWX7901654512     PSU4 FRU   psu      GOOD        fas2554-dal-1a,
                                                    fas2554-dal-1b
BPJWX7901654512     PSU3 FRU   psu      GOOD        fas2554-dal-1a,
                                                    fas2554-dal-1b
- Command "
system health subsystem show" disappears Service-Processor health is degraded. 
::> system health subsystem showSubsystem         Health----------------- ------------------SAS-connect       okEnvironment       okMemory            okService-Processor degradedSwitch-Health     okCIFS-NDO          okMotherboard       okIO                okMetroCluster      okMetroCluster_Node okFHM-Switch        okFHM-Bridge        okSAS-connect_Clusterok13 entries were displayed.