API disappears chassis state error
Applies to
- ONTAP 9.6 or later
- API
Issue
- Chassis state is error via API Link: https://cluster_mgmt_LIF/api/cluster/chassis?fields=*
{"records": [{"id": "BPJWX7901654512","state": "error","nodes": [{"name": "fas2554-dal-1a","uuid": "70e941f0-2cff-11ed-ac6f-00a098ca47ad","position": "top",............"name": "fas2554-dal-1b","uuid": "72b197d6-2cff-11ed-8dca-00a0987255ae","position": "bottom",- Command "
system chassis show" disappears chassis is degraded.
::> system chassis showChassis ID Status List of Nodes-------------------------- --------------- ----------------------------------BPJWX7901654512 degraded fas2554-dal-1a, fas2554-dal-1b- Command "
system chassis fru show" disappears controller is degraded
::> system chassis fru show
Chassis ID FRU Type State Nodes Sharing the FRU
------------------- ---------- -------- ----------- -----------------------
BPJWX7901654512 fas2554-dal-1b
controller
degraded fas2554-dal-1b
BPJWX7901654512 fas2554-dal-1a
controller
ok fas2554-dal-1a
BPJWX7901654512 PSU1 FRU psu GOOD fas2554-dal-1a,
fas2554-dal-1b
BPJWX7901654512 PSU2 FRU psu GOOD fas2554-dal-1a,
fas2554-dal-1b
BPJWX7901654512 PSU4 FRU psu GOOD fas2554-dal-1a,
fas2554-dal-1b
BPJWX7901654512 PSU3 FRU psu GOOD fas2554-dal-1a,
fas2554-dal-1b
- Command "
system health subsystem show" disappears Service-Processor health is degraded.
::> system health subsystem showSubsystem Health----------------- ------------------SAS-connect okEnvironment okMemory okService-Processor degradedSwitch-Health okCIFS-NDO okMotherboard okIO okMetroCluster okMetroCluster_Node okFHM-Switch okFHM-Bridge okSAS-connect_Clusterok13 entries were displayed.