CONTAP-252261: NVMe drive failure in remote plex of MetroCluster configuration impacts NFS service
Issue
In [EMS] logs-[scsi.cmd.checkCondition:error]: Disk device 0v.i2.3L33: Check Condition: CDB 0x2a:37e2f0f0:0001: Sense Data SCSI:aborted command - (0xb - 0x90 0x6 0xfa)(11125)] -[disk.timeout.flush.start:debug]: Aggressive timeout flush started on disk 0v.i1.3L33.] -[scsi.cmd.notReadyConditionEMSOnly:debug]: Disk device 0v.i1.1L10: Device returns not yet ready: CDB 0x2a:37e2f0f0:0001: Sense Data SCSI:not ready - (0x2 - 0x4 0x0 0x82)(32559).] -[raid.label.io.writeError:notice]: Label write on Disk /aggr_data_01/plex1/rg1/0v.i1.3L10P2 Shelf 0 Bay 30 [NETAPP X4002S172A3T8NTE NA03] S/N [S3N8NX0M100111NP002] UID [XXXXX] failed with storage error disk operation timed out. The system will stop using the disk for I/O operations.] -[wafl.cp.toolong:error]: Aggregate aggr_data_01 experienced a long CP.] -[Nblade.nfsLongRunningOp:debug]: Detected a long running network process operation. The client IP address:port is 10.10.10.1:888. The local IP address:port is 10.10.10.20:2000. The protocol requesting the operation is NFS3. ...]