Single PHY disabled on IOM
Applies to
- Fabric MetroCluster
- ONTAP 9
- DS224C
- ATTO FB7600N
Issue
A single PHY is reported as 'DIS/INVWD' (disabled)
Example:
::> node run -node ClusterA-01 -command "storage show shelf"...
Shelf name: SiteA_SW1:11.shelf15
Shelf id: 15
Channel: SiteA_SW1-1_SAN2:11
Module: B
Shelf UID: 00:00:00:00:00:00:00:00
Shelf S/N: 000000000000000
Term switch: N/A
Shelf state: ONLINE
Module state: OK
Partial Path Link Invalid Running Loss Phy CRC Phy
Disk Port Timeout Rate DWord Disparity Dword Reset Error Change
Id State Value (ms) (Gb/s) Count Count Count Problem Count Count
--------------------------------------------------------------------------------------------
...
[HST8] OK 7 12.0 0 0 0 0 0 3
[HST9] OK 7 12.0 0 0 0 0 0 3
[HST10] DIS/INVWD 7 NA 891967 889948 0 0 0 6
[HST11] OK 7 12.0 0 0 0 0 0 3
...