"DomainMismatchFromNodeToShelf_Alert" is reported on MetroCluster IP switch
Applies to
- ONTAP 9
- MetroCluster IP
- NS224 Shelves - Switch attached
- Cisco 9336C-FX2
Issue
"DomainMismatchFromNodeToShelf_Alert" is reported on MetroCluster IP switch:
Node ClusterA-02Monitor system-connectAlert ID DomainMismatchFromNodeToShelf_AlertAlerting Resource Switch-04Subsystem SAS-connect_ClusterIndication Time Fri Jul 25 08:52:47 2025Perceived Severity MajorProbable Cause Configuration_errorDescription The storage domain between the nodes ClusterA-01, ClusterA-02 and switch Switch-04 is different from the domain between the switch and shelves 4.40, 4.50, 4.60, 4.70.Corrective Actions Connect the switch Switch-04 to both the node and the shelves with the same storage domain, following the guide applicable to your shelf.Possible Effect This issue will affect conversions to direct-attached storage.Additional Information Switch Name: Switch-04Nodes: ClusterA-01, ClusterA-02Ports: ClusterA-01:e10a, ClusterA-02:e10aConnected Shelves: 4.40, 4.50, 4.60, 4.70Nodes Connected to Switch Port Range A: Switch-03, Switch-04Nodes Connected to Switch Port Range B:Alerting Resource Name Switch name: Switch-04- The alert first triggered during initial installation or maintenance activity.
- System Storage Configuration reports "Quad-Path" HA.
- The system is currently cabled correctly as per: