'InterconnectAdapterOfflineAlert' reported on FCVI port
- Views:
- 17
- Visibility:
- Public
- Votes:
- 0
- Category:
- ontap-9
- Specialty:
- metrocluster
- Last Updated:
- 4/3/2025, 11:38:39 AM
Applies to
- ONTAP 9
-
Stretch MetroCluster
Issue
'InterconnectAdapterOfflineAlert'
reported on FCVI port 0f in a two-node bridge-attached stretch MetroCluster with no switches.
::> system health alert show
Node: node-01
Alert ID: InterconnectAdapterOfflineAlert
Resource: fcvi_device_0
Severity: Major
Indication Time: Tue Mar 18 09:18:56 2025
Suppress: false
Acknowledge: false
Probable Cause: Physical link on port 0f is offline.
Possible Effect: DR protection of NVRAM mirror might be compromised.
Corrective Actions: 1. Ensure that the FC-VI link has not been tampered with.
EMS events:
Tue Aug 20 12:55:29 +0000 [node-01: ispfcvi2500_port2: fcvi.update.link.state:notice]: FC-VI adapter: Physical link is down on port 0f.
Tue Aug 20 12:55:29 +0000 [node-01: ispfcvi2500_port2: fcvi.link.down:notice]: params: {'alertId': 'InterconnectAdapterOfflineAlert', 'alertingResource': '500a098103b11710', 'alertingResourceName': '0f', 'possibleEffect': 'DR protection of NVRAM mirror might be compromised.', 'probableCause': 'Cable_tamper', 'probableCauseDescription': 'Physical link on port 0f is offline.', 'additionalInfo': 'None'}
Tue Aug 20 12:55:30 +0000 [node-02: ispfcvi2500_port2: fcvi.update.link.state:notice]: FC-VI adapter: Physical link is down on port 0f.
Tue Aug 20 12:55:30 +0000 [node-02: ispfcvi2500_port2: fcvi.link.down:notice]: params: {'alertId': 'InterconnectAdapterOfflineAlert', 'alertingResource': '500a098103b11790', 'alertingResourceName': '0f', 'possibleEffect': 'DR protection of NVRAM mirror might be compromised.', 'probableCause': 'Cable_tamper', 'probableCauseDescription': 'Physical link on port 0f is offline.', 'additionalInfo': 'None'}