SANtricity host performance degradation due to marginal drive
Applies to
- NetApp E-Series
- NetApp SANtricity
Issue
- SANtricity host reports performance issues
- The recovery guru file found in Support bundle and AutoSupport reports the following failure entry:
Failure Entry 1: DEGRADED_DRIVE_PATH-Recovery Failure Type Code: 76
- The major event log (MEL) found in Support bundle and AutoSupport reports the following event:
Timeout on drive side of controller
.
A:8/7/22, 6:51:31 AM (06:51:31) 9300 100d Timeout on drive side of controller - Shelf 99, Bay 2
A:8/7/22, 6:51:27 AM (06:51:27) 9299 100d Timeout on drive side of controller - Shelf 99, Bay 2
A:8/7/22, 6:51:24 AM (06:51:24) 9298 100d Timeout on drive side of controller - Shelf 99, Bay 2
- MEL may report
Drive channel set to Degraded - Drive-side
duringTimeout on drive
.
A:8/7/22, 6:47:24 AM (06:47:24) 9287 100d Timeout on drive side of controller - Shelf 99, Bay 2
A:8/7/22, 6:47:16 AM (06:47:16) 9286 1209 Drive channel set to Degraded - Drive-side: channel 2 <--CRITICAL
A:8/7/22, 6:47:16 AM (06:47:16) 9285 1513 Individual drive - Degraded path - Drive-side: channel 2 <--CRITICAL
A:8/7/22, 6:47:16 AM (06:47:16) 9284 100d Timeout on drive side of controller - Shelf 99, Bay 2