Issue

  • SCV sometimes selects wrong SVM as a backup target; then fails
  • vmcontrol_<JOB_ID>.log shows that SCV selects wrong SVM by using duplicate NFS IP

DEBUG <HOST> --- [tp1694819250-10] c.n.a.d.VsphereDiscoveryManager          : Datastore type is NFS
DEBUG <HOST> --- [tp1694819250-10] c.n.a.m.DatastoreStorageDetailsCache     : Calling GetNasStorageInfo with NFS LIF <IP> and exportPath <EXPORTPATH>
..
DEBUG <HOST> --- [tp1694819250-10] c.n.a.m.DatastoreStorageDetailsCache     : Calling GetNasStorageInfo with NFS LIF finished
DEBUG <HOST> --- [tp1694819250-10] c.n.a.m.DatastoreStorageDetailsCache     : Storage footprint found for nfsLif <IP> and exportPath <EXPORTPATH>:  ipAddress null vserverName <SVM> volumeName <VOLUME> junctionPath <JUNCTIONPATH> isLocatedOnFGfalse

  • Job-<JOB_ID>.log shows request is executed against wrong SVM; then fails

Example:

[DBG] Running Command New-NcSnapshotMulti controller name : <IP>, vserver : <SVM>
[ERR] API exception
[ERR] Failed to run a command New-NcSnapshotMulti
[DBG] ex.Message : Invalid input. Reason: Operation allowed only on Read_Write (RW) volumes. 
[DBG] ex.InnerException.Message : Invalid input. Reason: Operation allowed only on Read_Write (RW) volumes. 
..
[ERR] Error: Snapshot operation failed, Exception:Failed to run a command New-NcSnapshotMulti

  Invalid input. Reason: Operation allowed only on Read_Write (RW) volumes.

Note: Error can be varied depends on the configuration

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.