CAIQUM-3385: AUXCopy failed for MetroCluster volumes after planned switchover and switchback
Issue
CommVault (CV) AUX copy jobs fail after a planned switchover and switchback in MetroCluster.
/var/log/ocum/ocumserver.log:
Error occurred while adding list of snapshots to Dataset id dataset_uuid:app_type=OCUM,type=storage_service_subscription,uuid=dataset_uuid, Source Copy [774]. Error Message = [Failed to get subscription list from OnCommand server:um_server_fqdn.Error returned:[13001][Internal error]].Check streams information for more details.Source: um_server_fqdn, Process: AuxCopy
Failed to conform members of subscription
context:[vol name]. OnCommand Server:[UM server Name]. Error returned:[24012][Object is not subscribed to storage service 'vol name'.]
/var/log/ocum/ocumserver.log:
INFO [oncommand] [taskScheduler-2] [c.n.d.p.s.SnapshotExpirationService] Deletion of snapshot snapshot_name on volume svm_name:/volume_name failed with error: Data ONTAP reported error code (13024), message: 'Snapshot copy snapshot_name' of volume 'volume_name' on Vserver 'svm_name' has not expired or is locked. Use the "snapshot show -fields owners, expiry-time" command to view the expiry and lock status of the Snapshot copy.'