    • https://kb.netapp.com/Cloud/Cloud_Volumes_ONTAP/Panic_after_syncmirror_plex_failure_PANIC_MSG_Process_mgwd_unresponsive
      Applies to Cloud Volumes ONTAP (CVO) Amazon Web Services (AWS) Issue MGWD panic after losing access to several disks PANIC MSG = Process mgwd unresponsive for 839 seconds (mgwd startup: "(4341)") in p...Applies to Cloud Volumes ONTAP (CVO) Amazon Web Services (AWS) Issue MGWD panic after losing access to several disks PANIC MSG = Process mgwd unresponsive for 839 seconds (mgwd startup: "(4341)") in process nodewatchdog on release 9.8P1 (C)
    • https://kb.netapp.com/Cloud/BlueXP/Cloud_Manager/AWS_connector_failed_to_upgrade
      Applies to Cloud Manager Connector using proxy AWS cloud platform Issue AWS connector failed to upgrade.
    • https://kb.netapp.com/Cloud/BlueXP/Cloud_Manager/Does_shutdown_BlueXP_Connector_for_maintenance_affect_Client_I_O_access
      Applies to BlueXP Connector Answer No, it doesn't affect client I/O access. Additional Information additionalInformation_text
    • https://kb.netapp.com/on-prem/solidfire/Element_OS_Kbs/How_to_reboot_an_Element_storage_node
      This article outlines the procedure to reboot a storage node that is running Element Software. In rare instances, it may be necessary to reboot a storage node that is running Element software. This s...This article outlines the procedure to reboot a storage node that is running Element Software. In rare instances, it may be necessary to reboot a storage node that is running Element software. This should be done only when needed and under the direction of NetApp Support.
    • https://kb.netapp.com/on-prem/ontap/OHW/OHW-KBs/Host_reboot_causes_other_hosts_to_lose_FC_connections
      Applies to NetApp AFF-A200 Brocade Fibre Channel (FC) switches Windows and VMware ESXi hosts Issue When a host connected to NetApp storage via Brocade FC switches reboots, other hosts may lose connect...Applies to NetApp AFF-A200 Brocade Fibre Channel (FC) switches Windows and VMware ESXi hosts Issue When a host connected to NetApp storage via Brocade FC switches reboots, other hosts may lose connection to their NetApp FC LUNs
    • https://kb.netapp.com/on-prem/ontap/DP/SnapMirror/SnapMirror-KBs/TDP_initialization_interrupted_during_CVO_reboot
      During initialization of a TDP SnapMirror to CVO, the CVO was rebooted and the volume was left in a inconsistent state and offline. vol online: Error onlining volume "SVM:volume". Unable to set volume...During initialization of a TDP SnapMirror to CVO, the CVO was rebooted and the volume was left in a inconsistent state and offline. vol online: Error onlining volume "SVM:volume". Unable to set volume attributes for volume "volume" on Vserver "SVM". Reason: Volume was left in an inconsistent state by an aborted copy or an aborted snapmirror initial (level 0) transfer. In order to bring it online, you must either destroy and recreate the volume, or complete an initial snapmirror transfer or copy.
    • https://kb.netapp.com/on-prem/E-Series/SANtricity-OS-KBs/E-Series_EF600_unexpected_reboot_due_to_ancient_IO_with_reason_0x429c002
      Applies to E-Series EF600 Santricity OS version is earlier than 11.81 Issue Controller experienced unexpected reboot for ancient I/O. This triggered a core dump collection. ---- Log Entry #18 (Core 1)...Applies to E-Series EF600 Santricity OS version is earlier than 11.81 Issue Controller experienced unexpected reboot for ancient I/O. This triggered a core dump collection. ---- Log Entry #18 (Core 1) Jan-08-2024 10:30:59 AM ---- Reboot due to ancient IO, scsiOp=0x1464bedc0 poolId=0 opCode=28 age=330000ms 2024-01-08 08:57:17.131785 rebootReason 0x429c002, rebootReasonExtra 0x0
    • https://kb.netapp.com/Cloud/Cloud_Volumes_ONTAP/Single_node_Azure_CVO_reboots_without_Azure_maintenance_events
      Azure CVO Single Node No Maintenance Events like freeze or NIC detach reboot Hyper-V shutdown of guest VM Single node Azure CVO is not reachable for an hour and rebooted Fri May 28 02:02:00 -0400 [Clu...Azure CVO Single Node No Maintenance Events like freeze or NIC detach reboot Hyper-V shutdown of guest VM Single node Azure CVO is not reachable for an hour and rebooted Fri May 28 02:02:00 -0400 [Cluster-01: mgwd: clus.reboot.rebootDetected:notice]: Cluster reboot was detected at 01/01/2021 00:00:00. Sequence number for the cluster reboot was 5. Estimated beginning time of the cluster reboot was 01/01/2021 CVO was stopped and Azure activity log showed that it was stopped by Cloud Manager.
    • https://kb.netapp.com/on-prem/ontap/Perf/Perf-KBs/High_disk_latency_after_upgrade_due_to_Flash_Cache_options_being_disabled
      Applies to ONTAP 9.3 and later External cache options Issue High latency is seen after an ONTAP upgrade from 9.3 to higher releases Note: This can be seen due to an Active IQ alert and not due to late...Applies to ONTAP 9.3 and later External cache options Issue High latency is seen after an ONTAP upgrade from 9.3 to higher releases Note: This can be seen due to an Active IQ alert and not due to latency Disk utilization is at 100% but before was lower before upgrade Flash Cache options are off Cluster1::> system node external-cache show Node enabled rewarm mbuf-inserts pcs-size hya-caching ---------- ------- ------ ------------ -------- ----------- node1 true false false 256 false
    • https://kb.netapp.com/Legacy/SnapManager/SnapDrive_loses_Transport_Protocol_Settings_after_reboot_if_SVM_management_LIF_is_unreachable
      SnapDrive loses Transport Protocol Settings after reboot if the SVM management LIF is unreachable. The following error message is reported in the Snpdrvdbg.log: Or the following error message can be s...SnapDrive loses Transport Protocol Settings after reboot if the SVM management LIF is unreachable. The following error message is reported in the Snpdrvdbg.log: Or the following error message can be seen, if RPC default is active, also in the SnpDrvDbg.log: Unable to get filer version for '<SVM>'. Error: RPC Error - The RPC server is unavailable. Failed to get Data ONTAP version running on the storage system <SVM> as it is not reachable.
    • https://kb.netapp.com/on-prem/ontap/ontap-select/Select-KBs/ONTAP_Select_Node_Unexpectedly_Restarted
      Applies to NetApp ONTAP Select VMware ESXi Description An ONTAP Select node/VM restarted unexpectedly restarted and automatically returned online