Applies to AFF-A700 FAS9000 Issue After a power outage the node reports warning during the first boot WARNING: The NVRAM DIMM1 has caused UECC in the past. WARNING: The NVRAM DIMM2 has caused UECC in ...Applies to AFF-A700 FAS9000 Issue After a power outage the node reports warning during the first boot WARNING: The NVRAM DIMM1 has caused UECC in the past. WARNING: The NVRAM DIMM2 has caused UECC in the past. Please replace it as soon as possible!!! *******************************************************
Applies to After a power outage one node does not come back online system health alert show point out PSU2 issue cluster::> system health alert show Probable Cause: PSU2 FRU is off. The nodes in this ...Applies to After a power outage one node does not come back online system health alert show point out PSU2 issue cluster::> system health alert show Probable Cause: PSU2 FRU is off. The nodes in this chassis are Possible Effect: The system might switch off if the other redundant power supply units (PSUs) become faulty. Check PSU2 FRU and switch it on. Refer to the Hardware specification guide for more information on the position of the power supply unit (PSU) and ways to check or replace it.
EMS log shows: NODE_B:rdb.recovery.failed:EMERGENCY]: Error: Unable to find a master. Unable to recover the local database of Data Replication Module: Management
Applies to ONTAP Select Issue Environment power issue causes ONTAP Select node/'s to go down ESXi hosts, Deploy node and ONTAP Select nodes powered on Running vol show at the clustershell shows vol's ...Applies to ONTAP Select Issue Environment power issue causes ONTAP Select node/'s to go down ESXi hosts, Deploy node and ONTAP Select nodes powered on Running vol show at the clustershell shows vol's are missing Running node run local then vol status shows all volumes online
raid type raid_dp in SK process config_thread on release 8.2.3P4 on Mon Feb 10 07:52:07 CET 2020version: 8.2.3P4: Fri May 29 14:06:54 PDT 2015compile flags: x86_64Writing panic info to HA mailbox disk...raid type raid_dp in SK process config_thread on release 8.2.3P4 on Mon Feb 10 07:52:07 CET 2020version: 8.2.3P4: Fri May 29 14:06:54 PDT 2015compile flags: x86_64Writing panic info to HA mailbox disks.HA: current time (in sk_msecs) 128169944521 (in sk_cycles) 299073053244098161CF monitor: takeover will occur on reboot If the shelf containing root aggregate disks, which includes mailbox disks, goes offline, partner will be unable to takeover and will generate Active IQ alert:
Applies to ONTAP Select Issue After power outage, ONTAP Select is stuck at VLOADER. Any attempt to boot fails with VLOADER> boot can't find 'kernel' or hangs indefinitely:
Applies to NetApp ONTAP Select NetApp ONTAP Select Deploy VMware ESXi HPE ProLiant DL380 Gen10 (or other vendors) Issue HPE ProLiant DL380 Gen10 ESXi hosts are experiencing issues where the datastores...Applies to NetApp ONTAP Select NetApp ONTAP Select Deploy VMware ESXi HPE ProLiant DL380 Gen10 (or other vendors) Issue HPE ProLiant DL380 Gen10 ESXi hosts are experiencing issues where the datastores used by OTS sporadically go into an "inaccessible" state. Rebooting the host temporarily restores connectivity but the OTS node is unable to boot as it will panic: PANIC: nvram_mgr: cannot read nvramfile/disk, err=5
Unexpected power outage causes ONTAP to boot with ‘Root Volume Recovery required’ message, '[cluster:callhome.root.vol.recovery.reqd:EMERGENCY]: Call home for ROOT VOLUME NOT WORKING PROPERLY: RECOVER...Unexpected power outage causes ONTAP to boot with ‘Root Volume Recovery required’ message, '[cluster:callhome.root.vol.recovery.reqd:EMERGENCY]: Call home for ROOT VOLUME NOT WORKING PROPERLY: RECOVERY REQUIRED'. KB articles provides recovery steps for ONTAP 9.4 or later and ONTAP 9.3 or earlier.
Applies to NetApp E-Series and EF-Series with expansion trays Description This article explains the symptoms that can be seen when an expansion tray loses and regains power.