Skip to main content
NetApp Knowledge Base

Search

  • Filter results by:
    • View attachments
    Searching in
    About 2 results
    • https://kb.netapp.com/on-prem/ontap/Perf/Perf-KBs/What_operations_are_categorized_under_Other_IOPS_in_ONTAP
      For NAS workloads (CIFS/NFS), anything that involves metadata or manipulation of a file or folder. Procedure 6: READ - Read From file Procedure 8: CREATE - Create a file Procedure 9: MKDIR - Create a ...For NAS workloads (CIFS/NFS), anything that involves metadata or manipulation of a file or folder. Procedure 6: READ - Read From file Procedure 8: CREATE - Create a file Procedure 9: MKDIR - Create a directory Procedure 10: SYMLINK - Create a symbolic link Procedure 12: REMOVE - Remove a File Procedure 14: RENAME - Rename a File or Directory Procedure 21: COMMIT - Commit cached data on a server to stable storage How do I tell what "other" NFS iops are being processed within my volume?
    • https://kb.netapp.com/on-prem/ontap/Perf/Perf-KBs/FlexGroup_has_high_latency_due_to_all_workload_on_single_constituent
      Increased latency observed for "other" ops (specifically READDIR but can be seen on GETATTR and other metadata ops) on the FlexGroup parent Example: Normally a 6 node A800 cluster may see 10 GB/s writ...Increased latency observed for "other" ops (specifically READDIR but can be seen on GETATTR and other metadata ops) on the FlexGroup parent Example: Normally a 6 node A800 cluster may see 10 GB/s writes before hitting Data Processing latency, but throughput may only be 1-2 GB/s for writes Latency may be seen on a single constituent Reads or Writes can show a large increase in latency when there is a large increase in Read/Write workload within a single constituent.