- View attachments
- https://kb.netapp.com/on-prem/ontap/da/NAS/NAS-KBs/High_CPU_utilization_due_SecD_memory_issueHigh hostOS CPU is coming from SecD load Thu Nov 19 20:37:06 CET [Node-01: secd: secd.rpc.server.request.dropped:debug]: The RPC secd_rpc_auth_user_id_to_unix_ext_creds sent from NBLADE_NFS was droppe...High hostOS CPU is coming from SecD load Thu Nov 19 20:37:06 CET [Node-01: secd: secd.rpc.server.request.dropped:debug]: The RPC secd_rpc_auth_user_id_to_unix_ext_creds sent from NBLADE_NFS was dropped by SecD due to memory pressure. 00000023.3d2753ed 03357f70 Mon Nov 23 2020 00:17:48 +01:00 [kern_secd:info:14174] [SECD MASTER THREAD] SecD RPC Server:Too many outstanding Generic RPC requests: sending System Error to RPC 217:secd_rpc_auth_user_id_to_unix_ext_creds Request ID:16082.
- https://kb.netapp.com/on-prem/ontap/Perf/Perf-KBs/Poor_performance_and_high_CPU_usage_in_a_single_node_due_to_a_degraded_DIMMNumber of correctable ECC since boot 60362216: Information about Correctable ECC: ECC error at DIMM-xx: CE-03-2106-18AEE039,ADDR 0x5959b3100,(Node(1), Memory controller(0), CH(0), DIMM(0), Rank(0), Ba...Number of correctable ECC since boot 60362216: Information about Correctable ECC: ECC error at DIMM-xx: CE-03-2106-18AEE039,ADDR 0x5959b3100,(Node(1), Memory controller(0), CH(0), DIMM(0), Rank(0), Bank Group(2), Bank(0x0), Row(0x52ad), Col(0x2c0)) Number of correctable ECC since boot 60427752: Information about Correctable ECC: ECC error at DIMM-xx: CE-03-2106-18AEE039,ADDR 0x8698e9d00,(Node(1), Memory controller(0), CH(0), DIMM(0), Rank(1), Bank Group(0), Bank(0x0), Row(0x7d3f), Col(0x70))
- https://kb.netapp.com/Legacy/AltaVault/Altavault_What_is_too_high_memory_usageApplies to Altavault 4.4.1 Answer Memory usage is monitored in the Memory Paging report If 100 pages are swapped every couple of hours, the AltaVault is functioning properly If thousands of pages are ...Applies to Altavault 4.4.1 Answer Memory usage is monitored in the Memory Paging report If 100 pages are swapped every couple of hours, the AltaVault is functioning properly If thousands of pages are swapped every few minutes, then the System is using a lot of Memory Additional Information
- https://kb.netapp.com/Cloud/BlueXP/DII/Data_Infrastructure_Insights_Workload_Security_data_collector_failed_with_correct_settings_in_firewall_and_ONTAPData Infrastructure Insights (DII) (formerly Cloud Insights) Cloud Workload Security data collector Cloud Workload Security portal shows failed status for some added SVMs /Data Collectors and details ...Data Infrastructure Insights (DII) (formerly Cloud Insights) Cloud Workload Security data collector Cloud Workload Security portal shows failed status for some added SVMs /Data Collectors and details show Error: Agent004 or Error: Agent008 ..{"error":{"code":"InternalError","details":[{"code":"InternalError","message":"External fpolicy server terminated.","target":"audit"}],"message":"Connector is in error state.
- https://kb.netapp.com/on-prem/ontap/DP/SnapMirror/SnapMirror-KBs/SnapMirror_transfer_fails_for_large_volumes_with_CSM__An_operation_did_not_complete_within_the_specified_timeout_windowFri Mar 18 09:05:04 CEST 2020 ManualUpdate[Oct 9 09:00:54]:9863154b-77e1-11e8-8090-00a09864b794 Operation-Uuid=2cab1a60-09fd-11eb-b869-00a09867f2a6 Group=none Operation-Cookie=0 action=Defer source=sv...Fri Mar 18 09:05:04 CEST 2020 ManualUpdate[Oct 9 09:00:54]:9863154b-77e1-11e8-8090-00a09864b794 Operation-Uuid=2cab1a60-09fd-11eb-b869-00a09867f2a6 Group=none Operation-Cookie=0 action=Defer source=svm1:vol1 destination=svm2:vol2 status=Failure message=Transfer failed.(Replication operation request failed from Cluster Id: "Source Cluster Id", Node Id: "Source NodeId" to Cluster Id: "Destination ClusterId", Node Id: "Destination NodeId" due to a network error(CSM: An operation did not complete w…
- https://kb.netapp.com/data-mgmt/SnapCenter/SC_KBs/SC_verification_failing_with_Insufficient_memory_available_in_the_buffer_poolApplies to SnapCenter Server (SC) SnapCenter Plug-in for Microsoft SQL (SCSQL) Microsoft SQL Server Issue SC verification failing for SQL User DBs SC job log Error: There is insufficient memory availa...Applies to SnapCenter Server (SC) SnapCenter Plug-in for Microsoft SQL (SCSQL) Microsoft SQL Server Issue SC verification failing for SQL User DBs SC job log Error: There is insufficient memory available in the buffer pool. An exception occurred while executing a Transact-SQL statement or batch.
- https://kb.netapp.com/data-mgmt/AIQUM/AIQUM_Kbs/How_to_check_the_CPU_and_Memory_Reservations_for_AIQUM_hosted_on_a_VMware_virtual_machineApplies to VMware hosted virtual machines Active IQ Unified Manager Description Article covers how to check the CPU and Memory Reservations.
- https://kb.netapp.com/on-prem/ontap/Ontap_OS/OS-KBs/WAFL_very_low_memoryApplies to All Flash arrays over FCP, iSCSI or NVMe ONTAP 9.6 ONTAP 9.7P1 ONTAP 9.7P2 Issue Multiple EMS events can be seen over time: wafl.memory.statusLowMemory wafl.memory.statusVeryLowMemory Reboo...Applies to All Flash arrays over FCP, iSCSI or NVMe ONTAP 9.6 ONTAP 9.7P1 ONTAP 9.7P2 Issue Multiple EMS events can be seen over time: wafl.memory.statusLowMemory wafl.memory.statusVeryLowMemory Rebooting the system clears the EMS events for a few days
- https://kb.netapp.com/on-prem/Switches/Broadcom-KBs/SanNav_does_not_start_all_the_services_after_installationApplies to San Nav 2.1.1 Brocade Issue A newly installed SanNav shows the status: # check-sannav-status.sh User has selected to execute command Following services are currently restarting dcm-xxx faul...Applies to San Nav 2.1.1 Brocade Issue A newly installed SanNav shows the status: # check-sannav-status.sh User has selected to execute command Following services are currently restarting dcm-xxx faultmanagement-backend Following services are currently down elasticsearch Select option to proceed. 1 → help 2 → execute 3 → return to main menu
- https://kb.netapp.com/Legacy/NetApp_HCI/OS/Can_memory_DIMM_be_replaced_in_H300_H500_H700Applies to H300E H300S H500E H500S H700E H700S Answer Memory for H300, H500 and H700 is not an FRU Replace the node Additional Information DIMM for H410C, H610C, H615C is FRU.
- https://kb.netapp.com/on-prem/ontap/OHW/OHW-KBs/Host_lun_IO_errors_and_wafl_low_memoryLUNs are online and mapped, but the host experiences I/O errors. Messages from the host: Mar 16 00:44:13 linux kernel: [2634397.672285] blk_update_request: I/O error, dev sddm, sector 106981280 Mar 16...LUNs are online and mapped, but the host experiences I/O errors. Messages from the host: Mar 16 00:44:13 linux kernel: [2634397.672285] blk_update_request: I/O error, dev sddm, sector 106981280 Mar 16 00:44:13 linux kernel: [2634397.672469] sd 7:0:1:19: [sddm] tag#72 FAILED Result: hostbyte=DID_ABORT driverbyte=DRIVER_OK EMS events on NetApp: Mon Mar 16 00:10:11 UTC [NetApp: wafl_exempt02: wafl.memory.statusVeryLowMemory:alert]: WAFL is running very low on memory, with 795MB remaining.