    • https://kb.netapp.com/data-mgmt/SnapCenter/SC_KBs/VMware_vSAN_datastore_configuration_causes_multiple_SCV_issues
      Applies to SnapCenter Plug-in for VMware vSphere (SCV) 4.4 VMware Virtual SAN (VSAN) Issue Create Resource Group or Edit Resource Group gets stuck in initializing when clicking Next on page General in...Applies to SnapCenter Plug-in for VMware vSphere (SCV) 4.4 VMware Virtual SAN (VSAN) Issue Create Resource Group or Edit Resource Group gets stuck in initializing when clicking Next on page General info & notification VM Restore wizard receives the following error when clicking Next in page Select scope Example:
    • https://kb.netapp.com/on-prem/solidfire/Element_OS_Kbs/Mellanox_switch_hung_in__System_is_initializing
      Applies to Mellanox switch SN2010 Issue On Mellanox switch CLI: System is initializing! This may take a few minutes
    • https://kb.netapp.com/on-prem/ontap/da/SAN/SAN-KBs/ONTAP_WAFL_Hung_Panic_may_impact_SAN_protocol_services
      Applies to ONTAP 9 Issue ONTAP WAFL Hung Panic may impact SAN protocol services Panic String: WAFL hung for netapp_agg0. in SK process wafl_exempt12 on release 9.10.1P1
    • https://kb.netapp.com/on-prem/ontap/DM/System_Manager/SM-KBs/ONTAP_System_Manager_hangs_in_the_Protect_Volumes_menu_and_errors_with_the_application_faced_an_error
      Applies to ONTAP System Manager 9.8+ SnapMirror SnapVault Issue Protect Volumes window loads / spins indefinitely when selecting a volume in ONTAP System Manager. The SnapMirror is available over the ...Applies to ONTAP System Manager 9.8+ SnapMirror SnapVault Issue Protect Volumes window loads / spins indefinitely when selecting a volume in ONTAP System Manager. The SnapMirror is available over the ONTAP CLI. The following error is observed in the Chrome browser debug "Console" tab. ERROR|osm4|1623231627638|Wed Jun 09 2021,12:41:39.938||The application faced an error. See log file for more details. main.613b586a5913e8baab0d.js:1:2709068
    • https://kb.netapp.com/data-mgmt/AIQUM/AIQUM_Kbs/After_Active_IQ_Unified_Manager_OVA_upgrade_to_9_9_the_virtual_machine_becomes_unresponsive
      Applies to Active IQ Unified Manager (AIQUM) 9.7 Active IQ Unified Manager (AIQUM) 9.8 Active IQ Unified Manager (AIQUM) 9.9 VMware OVA Issue After the VMware OVA upgrade, VMware Tools is crashing wit...Applies to Active IQ Unified Manager (AIQUM) 9.7 Active IQ Unified Manager (AIQUM) 9.8 Active IQ Unified Manager (AIQUM) 9.9 VMware OVA Issue After the VMware OVA upgrade, VMware Tools is crashing within a few minutes. The whole virtual machine (VM) becomes unresponsive. Restarting brings the virtual machine up, but only temporarily.
    • https://kb.netapp.com/data-mgmt/SnapCenter/SC_KBs/SCO_plugin_gets_stuck_while_being_upgraded_to_version_4.6
      SCO plugin configured with a user requiring sudo privileges SCO plugins gets stuck while being upgraded to version 4.6 and the upgrade never completes. Installation of the package "snapcenter_linux_ho...SCO plugin configured with a user requiring sudo privileges SCO plugins gets stuck while being upgraded to version 4.6 and the upgrade never completes. Installation of the package "snapcenter_linux_host_plugin.bin" failed on the host "hostname.domain.com" with ErrorCode:1, error: We trust you have received the usual lecture from the local System sudo: a terminal is required to read the password; either use the -S option to read from standard input or configure an askpass helper
    • https://kb.netapp.com/data-mgmt/SnapCenter/SC_KBs/SCV_VM_console_access_is_lost_after_upgrading_to_scv_4.5
      Applies to SnapCenter Plug-In for VMWare 4.5 (SCV) Issue Following an upgrade of SCV from version 4.4 to 4.5, the VMWARE Vsphere client throwed an error message while dismounting the DVD drive used to...Applies to SnapCenter Plug-In for VMWare 4.5 (SCV) Issue Following an upgrade of SCV from version 4.4 to 4.5, the VMWARE Vsphere client throwed an error message while dismounting the DVD drive used to mount the 4.5 iso upgrade image. Additionally, the connection to the Web Console of the SCV VM was lost. VMWAre Client showed an error to update the device '0'
    • https://kb.netapp.com/on-prem/Switches/Broadcom-KBs/ocade_Switch_Kernel_Panic__D_Cache_Search_Parity_Error
      Applies to Brocade FC Switch 6505 FOS 8.2.0b Issue FOS Kernel Panic: Software Fault:Kernel Panic causes switch to reboot or not to boot at all. errdump -a displays entries similar to: Example: [HAM-10...Applies to Brocade FC Switch 6505 FOS 8.2.0b Issue FOS Kernel Panic: Software Fault:Kernel Panic causes switch to reboot or not to boot at all. errdump -a displays entries similar to: Example: [HAM-1004], 16860, CHASSIS, INFO, Brocade6505, Processor rebooted - Software Fault:KernelPanic. The following can be observed in pdshow: Machine check in kernel mode. D-Cache Search Parity Error