High CPU in HOST domain, viewing TOP-BS from Weekly AutoSupports in Active IQ shows top consumer is CSM BTLS PID USERNAME THR PRI NICE SIZE RES STATE C TIME WCPU COMMAND 2402 root 1 -16 - 0K 20K CPU3 ...High CPU in HOST domain, viewing TOP-BS from Weekly AutoSupports in Active IQ shows top consumer is CSM BTLS PID USERNAME THR PRI NICE SIZE RES STATE C TIME WCPU COMMAND 2402 root 1 -16 - 0K 20K CPU3 3 39.0H 74.76% CSM BTLS 2404 root 1 -16 - 0K 20K CPU0 0 39.0H 73.58% CSM BTLS 2401 root 1 -16 - 0K 20K RUN 0 38.9H 73.49% CSM BTLS 2403 root 1 -16 - 0K 20K CPU2 2 38.9H 72.61% CSM BTLS
Applies to ONTAP 9 Active IQ Unified Manager Issue High CPU or DISK utilization is seen, possibly despite low IOPs This occurs when a deduplication job is running a scheduled volume efficiency scan No...Applies to ONTAP 9 Active IQ Unified Manager Issue High CPU or DISK utilization is seen, possibly despite low IOPs This occurs when a deduplication job is running a scheduled volume efficiency scan Node Performance Limit - System Node Utilization messages being received via Active IQ Unified Manager (AIQUM) Consistently seeing very high resource consumption on single node
Applies to ONTAP 9 OnCommand Unified Manager 9.5 Active IQ Unified Manager 9.6 Issue Very high utilization is observed in AIQUM when looking at the node Performance Capacity Used (PCU) PCU reports upt...Applies to ONTAP 9 OnCommand Unified Manager 9.5 Active IQ Unified Manager 9.6 Issue Very high utilization is observed in AIQUM when looking at the node Performance Capacity Used (PCU) PCU reports upto 200% Perf utilization Node utilization graph is relatively low.
Is High CPU utilization causing a performance issue? Looking at the Cluster Components, the two main CPU resources are: If these two components make up the majority of your latency, then CPU is the pr...Is High CPU utilization causing a performance issue? Looking at the Cluster Components, the two main CPU resources are: If these two components make up the majority of your latency, then CPU is the primary factor in overall latency. In most AFF systems, CPU is the primary contributor to latency. It would be a 'problem' only if the latency seen is higher than expected. As with UM, if these two components comprise the majority of latency, then CPU is the primary factor in overall latency
Applies to NetApp StorageGRID NetApp ONTAP FabricPool Description This procedure explains how to map out an StorageGRID S3 object to an ONTAP volume that uses FabricPool to tier cold data to StoreageG...Applies to NetApp StorageGRID NetApp ONTAP FabricPool Description This procedure explains how to map out an StorageGRID S3 object to an ONTAP volume that uses FabricPool to tier cold data to StoreageGRID. There are several scenarios where this may be helpful: Tracking down a volume with high tiering (read/write) activity to the capacity tier "StorageGRID" in performance investigations. Tracking down ONTAP Volume(s) during investigation of lost or quanrantined S3 objects in StorageGRID.