How to determine the disk firmware? To determine the current disk firmware version of the drive, you need to view the output of the How to verify it is up to date? When the Disk Drive & Firmware Matri...How to determine the disk firmware? To determine the current disk firmware version of the drive, you need to view the output of the How to verify it is up to date? When the Disk Drive & Firmware Matrix page appears, click the link to the firmware revision needed for drives attached to your system. Compare the output from the AutoSupport with the output of the Firmware Matrix. Also, it is possible to determine the disk firmware in the cluster shell:
Applies to ONTAP 9.5 and later Storage/Disk is attached through FiberChannel initiators All disks have up to date Firmware installed Issue Event log reporting hourly messages for disks with downrev fi...Applies to ONTAP 9.5 and later Storage/Disk is attached through FiberChannel initiators All disks have up to date Firmware installed Issue Event log reporting hourly messages for disks with downrev firmware: disk.fw.downrevWarning:error xx disks have downrev firmware
Applies to AIQCAsecure rules The AIQUM reports an invalid alert: Incident - Verify That SSD Mixing Is Correct Impact Area - Configuration Cluster FQDN - Cluster1.lab.netapp.com Trigger Condition - If ...Applies to AIQCAsecure rules The AIQUM reports an invalid alert: Incident - Verify That SSD Mixing Is Correct Impact Area - Configuration Cluster FQDN - Cluster1.lab.netapp.com Trigger Condition - If the SSD is configured, the total stack depth is dependent on the number of SSDs that are present. Controller is running in an unsupported configuration and may have performance issues or an increased disk failure rate. This alert is not valid because the SSD mixing is within limits
The drive is the data one in a 3 RAID-DP root aggregate Sun Apr 12 00:18:18 CEST [node_name: disk_latency_monitor: shm.threshold.highIOLatency:error]: Disk 0a.00.8 exceeds the average IO latency thres...The drive is the data one in a 3 RAID-DP root aggregate Sun Apr 12 00:18:18 CEST [node_name: disk_latency_monitor: shm.threshold.highIOLatency:error]: Disk 0a.00.8 exceeds the average IO latency threshold and will be recommended for failure. Wed Apr 22 18:21:48 CEST [node_name: disk_latency_monitor: shm.threshold.ioLatency:debug]: Disk 0a.00.8 has exceeded the expected IO latency in the current window with average latency of 182 msecs and average utilization of 28 percent.
Applies to ONTAP 9 Description After downloading new disk and shelf firmware files to the cluster nodes using the storage firmware download command, you wish to view the status of the background firmw...Applies to ONTAP 9 Description After downloading new disk and shelf firmware files to the cluster nodes using the storage firmware download command, you wish to view the status of the background firmware updates.