Skip to main content
NetApp Knowledge Base

Search

  • Filter results by:
    • View attachments
    Searching in
    About 23 results
    • https://kb.netapp.com/on-prem/Switches/Broadcom-KBs/Admin_Password_Recovery_for_Broadcom_Switch_BES-53248
      Applies to Broadcom BES-53248 switch Cluster network switch ONTAP 9 Description How to change a lost or locked-out admin password on the BES-53248 switch. If a password for a BES-53248 switch is eithe...Applies to Broadcom BES-53248 switch Cluster network switch ONTAP 9 Description How to change a lost or locked-out admin password on the BES-53248 switch. If a password for a BES-53248 switch is either lost or forgotten, follow the procedure in this article. If authentication fails only via SSH but works correctly via the local console, then follow this article to change the password lockout setting.
    • https://kb.netapp.com/Legacy/NetApp_HCI/OS/Are_Broadcom_BES-53248_switches_supported_with_NetApp_HCI
      Broadcom BES-53248 switches do not support separate bonding modes on different switch ports. Non-redundant ports: Ports on either of the peer switches that are not part of the VPC (ports P4 and S4). V...Broadcom BES-53248 switches do not support separate bonding modes on different switch ports. Non-redundant ports: Ports on either of the peer switches that are not part of the VPC (ports P4 and S4). VPC interfaces and non-redundant ports cannot be members of the same VLAN, i.e. a VLAN may contain VPC interfaces or a VLAN may contain non-redundant ports, but not both. In the case where all VPC member ports are UP, data traffic does not traverse the peer link.
    • https://kb.netapp.com/on-prem/Switches/Brocade-KBs/SAN_switch_marginal_status_due_to_known_limitation_regarding_32_bit_time
      Switch reports Current Switch Policy Status MARGINAL due to expired certificate Switch name:root> seccertmgmt show -all FCAP Empty NA Empty Empty Empty Empty RADIUS Empty Empty Empty Empty Empty NA LD...Switch reports Current Switch Policy Status MARGINAL due to expired certificate Switch name:root> seccertmgmt show -all FCAP Empty NA Empty Empty Empty Empty RADIUS Empty Empty Empty Empty Empty NA LDAP Empty Empty Empty Empty Empty NA SYSLOG Empty Empty Empty Empty Empty NA HTTPS NA Empty Exist Expty Exist NA KAFKA NA Empty NA NA NA NA ASC NA Empty NA NA NA NA Current Switch Policy Status: MARGINAL ======================= Current Switch Policy Status: MARGINAL
    • https://kb.netapp.com/on-prem/Switches/Broadcom-KBs/Brocade_SanNav_shows_thousands_of_Java_threads
      Applies to Brocade SanNav 2.1.1 Issue The number of java threads keeps increasing from the time of installation: Restarting SanNav services seem to help temporarily
    • https://kb.netapp.com/on-prem/Switches/Broadcom-KBs/How_to_disable_BMC_access_on_a_Broadcom_BES-53248_switch
      Applies to Broadcom BES-53248 BMC Access Description This article describes the procedure to disable all external access to the BMC on Broadcom BES-53248 switches. Including: How to disable the BMC We...Applies to Broadcom BES-53248 BMC Access Description This article describes the procedure to disable all external access to the BMC on Broadcom BES-53248 switches. Including: How to disable the BMC Web GUI How to disable BMC IPMItool access How to disable BMC SSH access
    • https://kb.netapp.com/on-prem/Switches/Broadcom-KBs/Unable_to_deploy_Broadcom_s_SANnav_appliance
      2020-09-08T15:00:32.743+02:00 verbose OVFTool[13800] [Originator@6876 sub=Default] Curl_perform error code 3 (URL using bad/illegal format or missing URL) 2020-09-08T15:00:32.790+02:00 verbose OVFTool...2020-09-08T15:00:32.743+02:00 verbose OVFTool[13800] [Originator@6876 sub=Default] Curl_perform error code 3 (URL using bad/illegal format or missing URL) 2020-09-08T15:00:32.790+02:00 verbose OVFTool[06204] [Originator@6876 sub=Default] Exception thrown: class boost::exception_detail::clone_impl >(Connection error: Failed to connect to host :80 due to URL using bad/illegal format or missing URL, please see the logs for more details)
    • https://kb.netapp.com/on-prem/Switches/Brocade-KBs/Unable_to_reset_root_Password_on_Brocade_G610
      Applies to Brocade G610 The procedure to reset the password is stuck at mounting the environment variables. scanning usb for storage devices... 1 Storage Device(s) found *** badly formed bootargs in e...Applies to Brocade G610 The procedure to reset the password is stuck at mounting the environment variables. scanning usb for storage devices... 1 Storage Device(s) found *** badly formed bootargs in environment for GOS 0 *** Hit ESC to stop autoboot: 0 2) Recover password. Boot PROM password has not been set. => setenv bootargs 'root=/dev/sda$prt rootfstype=ext4 console =ttys0, 9600 quite single' Saving Environment to NVRAM... Unknown command 'mount' - try 'help'
    • https://kb.netapp.com/on-prem/Switches/Brocade-KBs/HA_not_in_sync_due_to_MDD_panic
      Applies to Brocade DCX Brocade X6 directors FOS8.2.1c Issue Brocade director lost HA SYNC due to MDD panic
    • https://kb.netapp.com/on-prem/ontap/mc/MC-KBs/Command_not_found_Incomplete_command_when_loading_BES_53248_configuration_file
      Applies to Broadcom BES-53248 Issue When copying configuration file to the switch Command not found / Incomplete command error is returned. Example: (sw1)# copy tftp://root@<TFPT_server_IP>/tftproot/c...Applies to Broadcom BES-53248 Issue When copying configuration file to the switch Command not found / Incomplete command error is returned. Example: (sw1)# copy tftp://root@<TFPT_server_IP>/tftproot/config.rcf Command not found / Incomplete command. Use ? to list commands.
    • https://kb.netapp.com/on-prem/Switches/Brocade-KBs/Automatic_reboot_of_Brocade_FC_switch_after_NTP_warning
      Applies to Brocade Issue Switch automatically haReboot with many NTP query failures leading up to reboot Example: errdump -a WARNING, NTP Query failed: 255. CHASSIS, CRITICAL, haReboot is automaticall...Applies to Brocade Issue Switch automatically haReboot with many NTP query failures leading up to reboot Example: errdump -a WARNING, NTP Query failed: 255. CHASSIS, CRITICAL, haReboot is automatically triggered for warm recovery from OOM. CRITICAL, Rebooting the system for recovery - auto-reboot is enabled. CHASSIS, INFO, First failure data capture (FFDC) event occurred. CHASSIS, INFO, Processor rebooted - Reset.
    • https://kb.netapp.com/on-prem/Switches/Broadcom-KBs/Brocade_switch_PSU_not_recognized_after_hot_swap_without_reboot
      Applies to Brocade G620 Power Supply Unit (PSU) Issue After replacing the switch PSU with the new one, the PSU still shows up as faulty: Example: psshow -v : Power Supply #1 is OK Power Supply #2 is f...Applies to Brocade G620 Power Supply Unit (PSU) Issue After replacing the switch PSU with the new one, the PSU still shows up as faulty: Example: psshow -v : Power Supply #1 is OK Power Supply #2 is faulty fanshow : Fan 1 is Ok, speed is 8341 RPM Fan 2 is Ok, speed is 8553 RPM