    • https://kb.netapp.com/on-prem/ontap/OHW/OHW-KBs/What_do_storage_system_and_shelf_temperature_thresholds_mean
      The low critical and low warnings are -1C and the high warning is 48C and the high critical is 50C. When the warning levels are reached an AutoSupport will be generated and if the critical levels are ...The low critical and low warnings are -1C and the high warning is 48C and the high critical is 50C. When the warning levels are reached an AutoSupport will be generated and if the critical levels are reached the storage system will shutdown. Sensor 1 is in the shelf, sensor 2 is in the A module and Sensor 3 is in the B module. If the warning threshold is reached, a warning AutoSupport is generated and if the critical threshold is reached on a shelf it will not power off.
    • https://kb.netapp.com/on-prem/ontap/OHW/OHW-KBs/Temperature_Sensor_Warning_on_FAS2650_and_AFF_A200
      The shelf reports over-temperature on temprature sensor. Node1: dsa_worker3: ses.status.temperatureError:error]: DS224-12 (S/N SHFxxx) shelf 0 on channel 0b temperature error for Temperature sensor 11...The shelf reports over-temperature on temprature sensor. Node1: dsa_worker3: ses.status.temperatureError:error]: DS224-12 (S/N SHFxxx) shelf 0 on channel 0b temperature error for Temperature sensor 11: critical status; overtemperature failure. This module is on the rear of the shelf at the top left, on shelf module A. [ses.status.temperatureWarning:alert]: DS224-12 (S/N ***********) shelf 0 on channel 0b temperature warning for Temperature sensor 11: non-critical status.
    • https://kb.netapp.com/on-prem/ontap/OHW/OHW-KBs/Disks_missing_through_IOM12E_and_PSU_FAN_and_temperature_errors
      Thu Apr 08 06:12:57 +0000 [node_name: dsa_worker2: ses.status.procCplxError:alert]: DS224-12 (S/N SHFNC0123456789) shelf 0 on channel 0b Processor Complex error for Processor Complex 1: PCM on partner...Thu Apr 08 06:12:57 +0000 [node_name: dsa_worker2: ses.status.procCplxError:alert]: DS224-12 (S/N SHFNC0123456789) shelf 0 on channel 0b Processor Complex error for Processor Complex 1: PCM on partner not installed This module is on the unknown location. This module is on the rear of the shelf at the top left, on shelf module A. This module is on the rear of the shelf at the top right, on shelf module B.
    • https://kb.netapp.com/on-prem/solidfire/hardware_Kbs/How_to_clear_NVRAM_device_warning_fanInletAmbientTemperature_alerts
      NetApp SolidFire Active IQ gives error: NVRAM device warning fanInletAmbientTemperature alerts