Applies to E-Series Linux SANtricity Storage Manager 11.50 and above Issue Storage Manager command line interface (SMcli) is called every few minutes in a script to check status of multiple arrays Aft...Applies to E-Series Linux SANtricity Storage Manager 11.50 and above Issue Storage Manager command line interface (SMcli) is called every few minutes in a script to check status of multiple arrays After sometime the application will not work and will not start again until complete cleanup of SMcli files and re-install Example: Every few minutes running this script against say 45 arrays on the same SMcli application instance. SMcli -n E2624-AMS -c "show storageArray healthstatus;"
Applies to NetApp E-series E2800 SANtricity OS Windows OS SMcli Issue SMcli command failing with authentication error however using same credentials, Santricity System Manager could be accessed. D:\Pr...Applies to NetApp E-series E2800 SANtricity OS Windows OS SMcli Issue SMcli command failing with authentication error however using same credentials, Santricity System Manager could be accessed. D:\Program Files\SMcli\bin> SMcli 10.XX.XX.XX -f script1.txt -k -u admin -p “xxxxxxxx" Performing syntax check... The username or password is not correct. Please try again. SMcli failed.
Applies to Linux installation of SMcli All SMCli binaries Issue Whenever trying to run SMcli, the following error appears: SMcli -d an internal error, error code 12, has occurred. Possible causes incl...Applies to Linux installation of SMcli All SMCli binaries Issue Whenever trying to run SMcli, the following error appears: SMcli -d an internal error, error code 12, has occurred. Possible causes include: (1) The CLI session was run without administrator permissions, or (2) The software installation is incomplete or corrupt. Retry the CLI with administrator permissions or reinstall the software. If problems persist, contact your technical support engineer. SMcli failed.
Applies to NetApp E-Series Description An instruction on how to use SMcli on Arrays running 11.60 or 11.70 systems, they should be managed via Unified Manager.
Applies to All E-Series Platforms SANtricity Command Line Interface (CLI) Description This article describes the process to collect an E-Series support bundle using the command line interface (CLI):
Applies to SANtriciity Storage Manager Storage Manager Command Line Interface (SMcli or script editor window) E5600 Issue Commands issued to E-Series storage array using SMcli or script editor window ...Applies to SANtriciity Storage Manager Storage Manager Command Line Interface (SMcli or script editor window) E5600 Issue Commands issued to E-Series storage array using SMcli or script editor window are very slow in response.
Applies to EF300 and EF600 controller platforms DE460C Expansion Enclosures Issue SMCLI command "show storageArray powerInfo"; returns an error when issued on EF300 and EF600 controllers as well as DE...Applies to EF300 and EF600 controller platforms DE460C Expansion Enclosures Issue SMCLI command "show storageArray powerInfo"; returns an error when issued on EF300 and EF600 controllers as well as DE460C enclosures when used as expansions.